Set Tw Shutdown Time Value; Store A Machine State - Elgar TrueWave TW 5550 Operation Manual

Table of Contents

Advertisement

Operation
TW 3700 • TW 5550
3 .1 0 .1 1 S E T T W S H U T DOWN T I ME VAL U E
Press the Up arrow key until the display reads:
CONFIG
Press the ENT key.
Press the Up arrow key until the display reads:
CURRENT
Press the ENT key. The display will read:
TYPE FOLD or
TYPE SHUT
Press the Up arrow key. Assuming the present timeout value is 200 milliseconds, the
display will read:
SET DELAY
200
Either enter a new value in the 0-9 keys followed by the ENT key, or use the Left arrow
or Right arrow key to decrement/increment the timeout value followed by the ENT key.
Press ABC/BACK repeatedly to back out of menus and return to readback display mode.
3 .1 0 .1 2 S T OR E A MACH I NE S T AT E
Press the Up arrow key until the display reads:
STORAGE
Press the ENT key.
The display reads:
STORE
0
Either enter a new value in the 0-9 keys followed by the ENT key, or use the Left arrow
or Right arrow key to decrement/increment the value followed by the ENT key.
Press ABC/BACK repeatedly to back out of menus and return to readback display mode.