TW 3700 • TW 5550
RECALL
Read in from locations 0-99. The 99
1.
A Volts: 0.0
2.
B Volts: 0.0
3.
C Volts: 0.0
4.
A Volts Offset 0.0
5.
B Volts Offset 0.0
6.
C Volts Offset 0.0
7.
Frequency: 60.0
8.
A Current Limit: 5.0
9.
B Current Limit: 5.0
10.
C Current Limit: 5.0
11.
Current Limit Type Shutdown
12.
Current Limit Timeout 200 ms.
13.
Coupling Type: AC
14.
Sense Remote
15.
Internal Amplifiers Parallel Mode Off
16.
Voltage Range Low
17.
Chassis Quantity 1
18.
A Volt Limit: 156.0
19.
B Volt Limit: 156.0
20.
C Volt Limit: 156.0
21.
Phase Angle A : 0.0
22.
Phase Angle AB: 120.0
23.
Phase Angle AC: 240.0
24.
Clk Lock/Sync: Phase A Out
25.
Aux Input: Off
26.
IEC Load State: Normal
STARTUP
At power up, the TW either will automatically source voltage to the output or it will wait
in standby mode.
INIT RUN
Choose this setting to specify that the TW will automatically source voltage at
start-up.
INIT STANDBY
Choose this setting to specify that TW will begin in standby mode.
Elgar TrueWave
th
location is factory defaults:
Operation
3-11