Syntax: {3, samptime,numpoints,trigtype,trigchan,trigthresh,
pre-store,(extclock)
Use this syntax for non-realtime data collection.
Sample
Number of
Time
Points
>0 to
0 = Invalid
16000
1 to 12,000 =
Default
NON-REALTIME
= 0.5
mode and
number of
points to collect
Pre-store
Data
Record Time
4
0% to 100%
0 = None
1 =
Absolute
2 = Relative
Note: This is
different
from the
original CBL.
Default on
CBL was 0.
1
This parameter is ignored.
2
Hardware trigger only for Command 1 operation 5, 6, or 7; software trigger for all others.
3
Software trigger only.
4
Prestore is not valid for manual trigger or immediate trigger. Due to the delay in
determining the start of sample, the actual amount of prestore may be smaller than
the selected amount.
5
FASTMODE does not apply to the Sonic/Digital channels.
CBL 2 Technical Reference
1
,rectime,filter,fastmode }
Trigger Type
0 = Immediate
1 = Manual
2 = Rising edge/
rising edge
3 = Falling
edge/ falling
edge
4 = Rising edge/
falling edge
5 = Falling
edge/ rising
edge
6 = Single
sample
Filter
0 = None
1 = Savitzsky-Golay 5-point filter
2 = Savitzsky-Golay 9-point filter
3 = Savitzsky-Golay 17-point filter
4 = Savitzsky-Golay 29-point filter
5 = Uses Median Pruning 3-point
filter
6 = Uses Median Pruning 5-point
filter
Trigger Channel
0 = Disables
trigger
1 = CH1 (channel
2
must be active)
2 = CH2 (channel
3
must be active)
3 = CH3 (channel
3
must be active)
11 = CH11 (channel
3
must be active)
Trigger
Threshold
- channel
limit to +
channel
limit
(channel
limit is
determined
by sensor
attached to
the channel)
Default =
1V
FastMode
5
0 = OFF
(normal
operation)
1 = ON
(FASTMODE
6
sampling)
27