Command 2 Data Type; Command 3 Trigger Setup - Texas Instruments CBL 2 Reference Manual

Ti cbl 2 data collector: reference guide
Hide thumbs Also See for CBL 2:
Table of Contents

Advertisement

Syntax: {1, channel , operation,list of values }
Use this syntax to set up the digital output channel.
Channel
Operation
31 = Digital
0 = Clears the channel
Output
1-32 = Count (number
of data elements in list)
The CBL 2 outputs one element for each sample. Between samples, the output returns
to 0 unless the user has commanded the power to remain on (using Command 102, M1).
Caution: Using Command 102, M 1 can drain the CBL 2 batteries.
Command 2
This command is not used and should not be sent. However, it is included for
compatibility with older CBL 2 programs.
Command 3
This command sets up the trigger parameters for an experiment. It has three syntaxes.
Syntax: {3, .1}
Repeats last Command 3 (used to quickly collect new data).
Syntax: {3, samptime,numpoints, 0,0,0,0,0,0, filter }
Use this syntax for realtime data collection.
Sample Time
Number of Points
>0 to 16000
.1 = REALTIME mode
0 = Invalid
Default = 0.5
26
List of Values
Lists values output
to digital output
port
Data Type
Trigger Setup
Filter
0 = None
7 = Light Realtime tracking filter
8 = Medium Realtime tracking filter
9 = Uses Heavy Realtime tracking filter
Note: the list of values
must have one value
for each count.