RECYCLING SYSTEM

RECYCLING SYSTEM

RECYCLING WATER TANK, VACUUM GRID WITH FLOAT AND RECYCLING WATER

FILTER CLEANING (OPTIONAL)

1.
Place the machine in the area designed for water disposal and washing.
2.
Turn the ignition key (10) to "0" position.
3.
Lift the cover (A).
4.
Clean and wash with fresh water the cover (A), the tank (B) and the vacuum automatic shut-off screen (C).
Drain the water from the tank (B) by using the pipe (36).
5.
If necessary, release the retainers (D) and open the shield (C); then extract the float (E), clean all the components
and reinstall them.
6.
Check the tank cover gasket (F) for deterioration.
NOTE
The gasket (F) creates vacuum in the tank that is necessary for the vacuum of recycling water.
If necessary replace the gasket (F) after removing it from its housing (G). When reassembling the new gasket, install
its joint (H) in the rear center area as shown in the figure.
7.
Make sure that the gasket (F) mating surface (K) is integral and adequate for the gasket seal.
8.
Make sure that the compensation hole (I) is not clogged, otherwise clean it.
NOTE
The hole (I), allowing the air compensation in the cover cavity, generates vacuum in the tank.
9.
Unscrew the recycling filter (J), if equipped, by turning it counter-clockwise. Clean and wash the filter with fresh
water, then reinstall it.
10. Close the cover (A).