SERVICE MANUAL
SOLUTION FLOW CONTROL CABLE AND LEVER CHECK AND ADJUSTMENT
1.
Drain the recycling water, if any, from the related tank (70) by using the pipe (36).
2.
Drain the solution, if any, from the related tank (71) by using the pipe (37).
3.
Position the machine on a level ground.
4.
Turn the ignition key (10) to "0" position.
5.
Turn the solution flow control lever (4) to the "ECO" position (5).
6.
Slightly lift the machine left side and loosen the clamp (A) by releasing the sheath (B).
7.
Check that the faucet flow control lever (C) is at the left end (as shown in the figure), if not, turn it to the left end and
tighten the sheath (B) by using the clamp (A).
8.
Lower the machine left side to the floor.
18
Figure 5
909 5484 000(1)2004-03