SOLUTION FLOW CONTROL CABLE AND LEVER DISASSEMBLY

1.
Drain the recycling water, if any, from the related tank (70) by using the pipe (36).
2.
Drain the solution, if any, from the related tank (71) by using the pipe (37).
3.
Position the machine on a level ground.
4.
Turn the ignition key (10) to "0" position.
5.
Disconnect the battery connector (40).
6.
Close the solution faucet (A) from the right lower side of the machine.
7.
Slightly lift the machine left side and remove the hoses (B) and (C) from their fittings.
8.
Loosen the clamp (D) and release the sheath (E).
9.
Remove the cable (F) from the lever (G).
10. Connect a probe (cord or equivalent) to the cable end (F) (this operation is necessary to facilitate the insertion of
the cable inside the machine).
11. Lower the machine left side to the floor.
12. Remove the handle (H) from the lever (I), by using the control panel.
13. Unscrew the screws (J) and slightly lift the panel (K).
14. Unscrew the screws with the nut (L) and remove the lever assembly (I) from the panel (K).
15. Take the control cable (M) and the lever out of the machine, leaving the probe in its place (to facilitate the control
cable insertion).
16. Reassemble by carrying out the disassembly operations in the reverse order, by placing the clamp (D) on the sheath
(E) without tightening it.
17. Perform the Cable Adjustment, as described in the following procedure.