Solution Supply System; Solution Tank And Supply System Cleaning; Solution Filter Cleaning - Nilfisk-Advance BA 600S Service Manual

Table of Contents

Advertisement

SOLUTION SUPPLY SYSTEM

SOLUTION SUPPLY SYSTEM

SOLUTION TANK AND SUPPLY SYSTEM CLEANING

1.
Place the machine in the area designed for the detergent and recycling water disposal.
2.
Empty the solution tank (71) through the pipe (94).
3.
Turn the solution flow control lever (4) to the wide-open position, then operate the machine until the solution inside
the machine runs out.
4.
Turn the ignition key (10) to "0" position.
5.
Wash the tank (71) by using fresh water.
6.
Operate the machine until the solution inside the machine runs out.
7.
Carry out the solution filter cleaning (see the following procedure).

SOLUTION FILTER CLEANING

1.
Position the machine on a level ground.
2.
Turn the ignition key (10) to "0" position.
3.
Close the solution faucet (A) from the right lower side of the machine. The faucet (A) is closed when it is in position
(B) as to the pipeline; it is open when it is in position (C).
4.
Remove the transparent cover (D) and the strainer (E) from the left lower side of the machine (at the "FILTER"
mark); then clean and reinstall them on the holder (F).
NOTE
Correctly position the strainer (E) in the holder (F) housing (G).
5.
Re-open the faucet (A).
909 5484 000(1)2004-03
Figure 1
SERVICE MANUAL
S300621
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ba 650sBa 750s