7.3 Type tests and environmental conditions

Phenomena
ESD
RF field AM
modulated
Fast transient
Surge
RF conducted
Radiated emission
Conducted
emission
Degrees of protec-
tion provided by en-
closures
Dry heat
Cold
Damp heat
Shock
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de
Test
Description
EN 61000-4-2
Enclosure contact
Enclosure air
EN IEC 61000-4-3
Enclosure
EN 61000-4-4
Signal ports
Power ports
Ethernet ports
EN 61000-4-5
Ethernet ports
Power ports
I/O ports
EN 61000-4-6
All ports
EN 55032
Enclosure
EN 55032
DC power ports
Ethernet ports
EN 60529
IP30
EN 60068-2-2
storage +85 C,operation +75 C
EN 60068-2-1
storage -40 C
EN 60068-2-30
+55 C / +25 C, rel. humidity 95%, 6 h - 6 h
EN 60068-2-14
-40 C/+75 C, 3h/3h, 2 cycles, 3 K/min
Table 34: Type tests and environmental conditions
SmartFlex SR310
Test levels
6 kV
8 kV
10 V/m (80 – 1000 MHz)
10 V/m (1000 – 6000 MHz)
1 kV
1 kV
1 kV
1 kV
1 kV
1 kV
10 V/m (0,15 – 80 MHz)
Class B
Class B
Class B
46