RTCU LX2 pro Technical Manual V1.00
Advanced Automotive M2M/IoT Gateway
The analog inputs are made available at the same time as both normal analog inputs with an
operating voltage range of 0-10V DC, and as flex inputs.
When used as flex inputs, the inputs are multi-mode inputs that can be configured to operate as either
analog or digital inputs. When operating as a Flex input the operating range is from 0V to 30V DC
and is configurable as digital inputs with customized threshold values.
The flex inputs can also be used as digital inputs, behaving the same way as the normal digital inputs
with the same threshold values or using different threshold values for more advanced features.
The same flex input can be used for multiple digital inputs with different settings, e.g., different
threshold values or debounce timing.
Configuring the flex input for band matching allows triggering the digital inputs at specific values,
making it possible to connect circuits that generate different voltages for different states and then read
the state directly.
See the RTCU IDE documentation for more details about configuring the flex inputs as digital inputs.