RTCU LX2 pro Technical Manual V1.00
Advanced Automotive M2M/IoT Gateway
Connector X4: 6 pin SER1 connector
Pin
Name
1
TD
2
CAN2-H
3
CAN2-L
4
RD
5
GND
6
GND
Connector SER2: RJ45 (RS232) connector
Pin
Name
1
DSR
2
DCD
3
DTR
4
GND
5
RD
6
TD
7
CTS
8
RTS
Mini USB-B Connector
This USB port is for programming and communication with the RTCU IDE or other RACP-compliant
applications. A standard USB cable can be used between the device and the PC.
Logic IO ApS.
Holmboes Allé 14
8700 Horsens
Denmark
RD
4
GND
5
GND
6
Description
Transmit Data from serial port 1, RS232 compatible
CAN-bus 2 H-signal
CAN-bus 2 L-signal
Receive Data for serial port 1, RS232 compatible
Signal Ground
Signal Ground
1
2
3
DSR DCD DTR
GND
Description
Data Set Ready, RS232 compatible
Data Carrier Detect, RS232 compatible
Data Terminal Ready, RS232 compatible
Signal Ground
Receive Data for serial port 2, RS232 compatible
Transmit Data from serial port 2, RS232 compatible
Clear To Send, RS232 compatible
Request To Send, RS232 compatible
Page 13 of 39
1
TD
2
CAN2-H
3
CAN2-L
4
5
6
7
RD
TD
CTS
8
RTS
Ph: (+45) 7625 0210
Fax: (+45) 7625 0211
Email: support@logicio.com
www.logicio.com
Need help?