CONFIRM IT BEFORE YOU GET START

Ambient Temperature Range For Unit Operating
MODE
Temperature Range
Cool
17-35°C (62-95°F)
Dry
13-35°C (55-95°F)
Choose the right position
≥30cm(12in)
≥30cm(12in)
Energy Rating Information
The energy rating and noise information for this unit is based on the standard installation using an
un-extended exhaust duct (Diameter:150mm, Length:1.5m) without window slider adaptor or wall
exhaust adaptor A.
The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts(Diameter:150mm,
Length:1.5m + Diameter: 130mm, Length: 1.5m) .The Energy rating and noise information for unit
with 3 meters extended exhaust duct is not assessed.(For some models)
NOTE: We recommend that operating the unit at room temperature below 35°C . Since there is a
risk that the unit with 3 meters extended exhaust duct would not work at room temperature above
35°C under some extreme conditions, such as the lower air intake be blocked for 50%.
Exhaust Hose Installation
The exhaust hose and adaptor must be installed or removed in accordance with the usage mode.
For COOL,HEAT(heat pump type) or AUTO mode must be installed exhaust hose. For FAN, DRY or
HEAT (electrical heat type) mode must be removed exhaust hose.
How to Stay Cool with a New Portable Air Conditioner(For the models comply
with the requirements of Department Of Energy in US)
Because of a new federal test procedure for Portable Air Conditioners, you may notice that the
cooling capacity claims on portable air conditioner packaging are significantly lower than that of
models produced prior to 2017. This is due to changes in the test procedure, not to the portable
air conditioners themselves.
MODE
Heat(pump heat mode)
Heat(electrical heat mode)
13
Temperature Range
5-30°C (41-86°F)
30°C (86°F)
Your installation location should
meet the following requirements:
-Make sure that you install your
unit on an even surface to minimize
noise and vibration.
-The unit must be installed near a
grounded plug, and the Collection
Tray Drain (found on the back of the
unit) must be accessible.
-The unit should be located at least
30cm (12") from the nearest wall to
ensure proper air conditioning. The
horizontal louver blade should be at
least 50cm (19.7") away from
obstacles.
-DO NOT cover the Intakes, Outlets
or Remote Signal Receptor of the
unit, as this could cause damage to
the unit.