FOLLOW ME/TEMP SENSING feature
(On some models)
NOTE: This feature can be activated from the
remote control ONLY. The remote control serves
as a remote thermostat allowing for the precise
temperature control at its location.
To activate the Follow Me/Temp Sensing feature,
point the remote control towards the unit and
press the Follow Me/Temp Sensing button. The
remote control will send this signal to the air
conditioner until press the Follow Me/Temp
Sensing button again. If the unit does not receive
the Follow Me/Temp Sensing signal during any 7
minutes interval, the unit will exit the Follow Me/
Temp Sensing mode.
NOTE: This feature is unavailabe under FAN or
DRY mode.
AUTO-RESTART
If the unit breaks o unexpectedly due to the
power cut, it will restart with the previous
function setting automatically when the power
resumes.
Default Setting
When the air conditioner restarts after a power
failure, it will default to the factory settings
(AUTO mode, AUTO fan, 24°C (76°F)). This
may cause inconsistencies on the remote
control and unit panel. Use your remote
control to update the status.
Auto-Restart (some models)
In case of power failure, the system will
immediately stop. When power returns, the
Operation light on the indoor unit will flash. To
restart the unit, press the ON/OFF button on
the remote control. If the system has an auto
restart function, the unit will restart using the
same settings.
Three-minute protection feature
(some models)
A protection feature prevents the air
conditioner from being activated for
approximately 3 minutes when it restarts
immediately after operation.
AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the
air flow direction automatically:
· When the Power is ON, the louver opens fully.
· Press the SWING button on the panel or remote
controller to initiate the Auto swing feature. The
louver willl swing up and down automatically.
· Please do not adjust the louver manually.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted
operation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
NOTE:
Under cooling operation, when the ambient
temperature is lower than the setting temperature for
a period of time. The compressor and fan motor will
stop. When the ambient temperature is higher than
the setting temperature, the compressor and (or)
fan motor run.
Louver Angle Memory Function
(some models)
Some models are designed with a louver angle
memory function. When the unit restarts after a
power failure, the angle of the horizontal louvers
will automatically return to the previous position.
The angle of the horizontal louver should not be
set too small as condensation may form and drip
into the machine. To reset the louver, press the
manual button, which will reset the horizontal
louver settings.
Refrigerant Leak Detection System
(some models)
The indoor unit will automatically display "EC"
or "EL0C"or flash LEDS (model dependent )
when it detects refrigerant leakage.