Vega VEGAMIP R62 Operating Instructions Manual page 35

Table of Contents

Advertisement

Medium provides low
signal damping
Switching delay
VEGAMIP R62 • Receiving unit
Fig. 31: LED indication strip - Setting for products with strong signal damping
If there is strong buildup during operation, adjustment with buildup is
recommended. A short period of operation is probably sufficient to
create buildup, or buildup can be created artifically or imitated.
In applications with products providing only weak signal damping (eg
plastic granules, cereals), you should adjust the instrument to more
sensitive. This way, the VEGAMIP 62 switches very sensitively, even
with a relatively low coverage by the product.
Fig. 32: LED indicating strip - Setting for products with weak signal damping
You can adjust the switching delay with the help of the LED indicating
strip.
Push the two keys (7) and (8) simultaneously for approximately 2 s
until the LED indication flashes.
6 Setup