PRIOR TO USE
INITIALIZATION WHEN POWER OF LENS IS TURNED ON
After the power for the lens is turned on, the lens must be initialized.
・ The focus and zoom setting methods vary depending on the status of the respective servo/manual select knobs
of focus and zoom of the lens when the power is turned on.
①
When the knob is set to "Servo":
Both focus and zoom are automatically initialized.
②
When the knob is set to "Manual":
Focus and zoom are initialized by turning each ring manually.
When using a communication function such as LDS, always perform initialization. See the
following table for the details of the initialization method.
・
The iris setting method differs depending on the setting of the lens "function/mode changeover switch SW 1-
④"when the power is turned on, regardless of the setting of the iris mode changeover switch.
(Refer to Page E13.)
①
When set to ON:
Initialization is automatically performed.
②
When set to OFF:
Initialization is performed by manually turning the iris ring.
When using a communication function such as LDS or controlling the iris from an external device, be sure
to perform initialization.
Setting of Servo/Manual
Select Knob
Section of Lens
Focus
Zoom
Setting the lens function/
mode changeover
switch
Lens Components
IRIS
If the servo / manual select knob is set to servo in a state where the ring has not been turned to the specified
*1
angle and initialization is therefore not performed, focus / zoom starts initializa-tion automatically.
If the ring has not been turned to the predetermined angle and initialization has not been performed, turning
*2
ON the lens function/mode changeover switch SW 1 ④ causes the iris to automatically start initialization.
①Servo (Auto)
The focus operates and is initialized
automatically.
The zoom operates and is initialized
automatically.
① ON
The iris operates and initialization is
automatically performed.
② Manual
By turning the focus ring manually by about 60
degrees, the focus is initialized
(Turn the ring within a two-second period.)
By turning the zoom ring manually by about 60
degrees, the focus is initialized
(Turn the ring within a two-second period.)
② OFF
Initialization is performed by manually turning the iris
ring approx. 45°.
*2
(Turn the ring so that it moves between the open end
and the close end within two seconds.)
*1
.
*1
.