DIGITAL CAMERA XF56mmF1.2 R SIMPLE MANUAL -For Repair Centers without the Lens Repair Training WARNING THE COMPONENTS IDENTIFIED WITH THE MARK “ ” IN THE SCHEMATIC DIAGRAM AND THE PARTS LIST ARE CRITICAL FOR SAFETY. REPLACE THOSE COMPONENTS ONLY WITH THE COMPONENTS SPECIFIED IN THE SCHEMATIC DIAGRAM AND THE PARTS LIST.
Page 2
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- SAFETY CHECK-OUT During repair and safety checking, conduct the followings. 1. Check if there are unsoldered or poorly CAUTION: soldered connections. Check the entire...
Page 3
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- CONTENTS 1. List of Jigs······································································································ 4 2. Inspection······································································································· 5 3. Parts List ······································································································· 13 4. Appendix ······································································································· 15...
XF60 CIPA Resolution Chart Resolution Inspection Common with the XF60mmF2.4 R Macro XF56MM RESOLUTION ZJ02286-100 ---- Resolution Inspection New jig CHECK SOFTWARE ZJ01898-100 DUST CHART Lens dust for inspection ZJ01899-100 DUST CHART 2 *1: Please download them from Web server (https://cs-support-eid.fujifilm.co.jp).
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 2. Inspection 2-1. Inspection and Factory Settings <Applies only to general cameras for repair> Measuring Preparations for adjustment Method of adjustment Sequence...
Page 6
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- Measuring Preparations for adjustment Method of adjustment Sequence Item Mode equipment (measurement points, subject, other) (VRs, waveforms, required values) and jigs Aperture operation A(Aperture (1) Turn the Aperture ring.
Page 7
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 2-2. Lens Dust Check <Settings for Lens dust check> (1) Prepare a DUST CHART (ZJ01898-100) or DUST CHART2 (ZJ01899-100). (2) Wiped off dusts of lens surface.
Page 8
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 2-3. Resolution Inspection <Resolution Inspection operation flow> Resolution Inspection Start FAIL Resolution Inspection PASS Resolution Inspection End Repair operation flow * Be sure there are no problems...
Page 9
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- <Step 1> [Settings for Resolution Inspection] (1) Cut XF60 CIPA Resolution Chart (ZJ02018- Brightness of the resolution chart 100) like figure 2, and stick it on a Gray Chart Center: 500~850LX...
Page 10
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- <Step 3> [Resolution Inspection] (1) Download the software from the WEB and install the software to the PC. We have uploaded the “XF56MM RESOLUTION CHECK SOFTWARE (ZJ02286-100.zip)” on our website: (https://cs-support-eid.fujifilm.co.jp).
Page 11
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- (9) The center of the chart will appear. The chart and values determined by [Center resolution analysis] are displayed. By pressing the [Enter] key, the measurement continues in the order of “upper left” → “lower left” →”upper right” → “lower right”.
Page 12
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- (10) The measurement has been completed once “OK” is displayed for all of [Resolution measurement]. [Completing Resolution Inspection] <Resolution criteria> Center H: 2,500 lines or more...
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 3. Parts List 3-1. Packing and Accessories Ref No. Parts No. Description Common A111 A101 F012B013260720 TRAY A102 F100A12447A10 REAR CAP A103...
Page 14
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- MEMO...
Confidential: FUJIFILM Service Center Use Only XF56mmF1.2 R Simple Manual -For Repair Centers without the Lens Repair Training- 4. Appendix 4-1. List of Related Technical Updates Issued To ensure that after-sales service is performed accurately, keep a record here of the technical updates issued that cover this device.
Page 16
Confidential: FUJIFILM Service Center Use Only FinePix JX420 / JX430 Service Manual Midtown West, 7-3, Akasaka 9-chome, Minato-ku, Tokyo 107-0052, Japan...
Need help?
Do you have a question about the XF56mmF1.2 R and is the answer not in the manual?