※12 Configuration Set
UNIT OFF
ON
Preparation 10 sec.
System Check
10
Container ID
DILU1234567
Controller Date
DD/MM/YYYY
Controller Time
17 : 00
SoftwareVer.
3031
※12-1 Controller model
※12-2 Log Interval
※12-3 Optional Sensor Optional Sensor
※12-4 Reheat Coil
※12-5 Ventilation (FA)
※12-6 USDA Sensor Type
※12-7 Temp Unit
※12-8 Pressure Unit
※12-9 Ventilation Unit
※12-10 Container I.D.
※12-11 Controller Date Controller Date
※12-12 Controller Time Controller Time
※12-13 H006
Caution !!
1. Optional function setting is done at factory. Normally, setting change at
field is not necessary.
2. Ensure the circuit breaker is switched OFF after Configuration Set change.
OFF
[Initialize Menu]
Initialize Menu
PTI Menu
Manual Check
Config Set
Optional Function
USB Menu
Title display
Controller model DECOS Va or V
Log Interval
15, 30, 60, or 120 minutes
ON
OFF
ON
Reheat Coil
OFF
LOW-FLY : With FA sensor (Ventilator with insect screen)
Ventilation (FA)
LOW
OFF
Type 1
USDA Sensor Type
Type 2
Temp Unit
℃(Centigrade)or F(Fahrenheit)
Pressure Unit
kPa , psi or bar
Ventilation Unit
m3/h or CFM
Container I.D.
Mentioned in following page.
H006 function: Detect the time which temperature difference
between SS and DSS becomes 2℃ or over
OFF: Without H006 function
1: Time which temperature difference becomes 2℃ or over is more than 1 hour
H006
2: Time which temperature difference becomes 2℃ or over is more than 2 hour
3: Time which temperature difference becomes 2℃ or over is more than 3 hour
4: Time which temperature difference becomes 2℃ or over is more than 4 hour
5: Time which temperature difference becomes 2℃ or over is more than 5 hour
10: Time which temperature difference becomes 2℃ or over is more than 10 hour
Circuit Breaker OFF after
setting change
Config Set
Controller model
Log Interval
Optional Sensor
Reheat Coil
Ventilation (FA)
USDA Type
Temp Unit
Pressure Unit
Ventilation Unit
Container I.D.
Controller Date
Controller Time
H006
Setting    
: DRS sensor fitted
: DRS sensor not fitted
: Reheat coil fitted
: DRS Reheat coil not fitted
: With FA sensor (Ventilator without insect screen)
: Without FA sensor (Standard)
: ST9702-1 type USDA sensor
: NTC type USDA sensor (Standard)
2-14
DECOS Va
*12-1
60 min
*12-2
ON
*12-3
ON
*12-4
OFF
*12-5
Type 2
*12-6
C
*12-7
kPa
*12-8
m3/h
*12-9
DILU 1234567
*12-10
DD/MM/YYYY
*12-11
17 : 00
*12-12
*12-13
Charge ⇒