Daikin LX10F11B Service Manual page 91

Inverter container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru
No.
Inspection item
Damage of power cable
1
and plug
Inspection of condition of
2
internal wiring
Terminal looseness
3
inspection and retighten if
necessary
Condition of monitoring
4
receptacle cover
5
Condition of PC port cover
6
Fuse conditions
Magnetic switch contact
7
point inspection and
replacement
8
Electric insulation check
9
Temperature sensor
10 Humidity sensor
PT/CT (voltage and
11
current) Alarm indication
Pressure sensor Alarm
12
indication
13 Condenser fan motor
14 Evaporator fan
15 Condenser fan
Inspection content
1) Magnetic switch
2) Electronic connection
Open or short connection
1) Contact point inspection
2) Replace the contact on
evaporator fan motor
3) Replace the contact on
condenser fan motor
1) Power cable and plug
2) Compressor
3) Evaporator fan motor
4) Condenser fan motor
1) Installation condition of sensors
2) Inspection of sensor and sensor
cable for damage
3) Alarm indication
Inspect every year.
Inspection of bearing
Deformation and damage inspection
Deformation and damage inspection
3-9
2nd year 4th year 8th year