Rack Adapters; GROUP 11: Sierra Products 2 We recommend that you use only the power cord supplied with this device 3 Download up-to-date Kramer user manuals from our Web site: http://www.kramerelectronics.com 4 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com...
The TBUS-6 is height-adjustable. The cover that opens and closes manually retracts into the unit to remain out of sight when the TBUS-6 is in use. When closed, all cables and connectors are out of sight under the anodized cover.
Your TBUS-6 Beware of sharp edges on the inner and outer rim of the mounting plate and on the lid of the TBUS-6. They can cause serious injury. Do not place heavy objects on top of the TBUS-6. Your TBUS-6 Figure 2 and Table 1 define the unit.
Your TBUS-6 Table 1: TBUS-6 Table Connection Bus Features Feature Function Connecting Surface See Figure 3 and Table 2 Black Anodized Lid Covers the connecting surface, leaving the table surface neat and tidy Mounting Plate Outer Rim Fits over the table surface...
2. Adjust the height of the connecting surface (see section 5.2). 3. Install optional insert (see section 5.3). 4. Install the TBUS-6 in the cut-out opening (see section 5.4). 5. Connect the cables (see section 5.5). 5.1 Cutting an Opening in the Table To cut an opening in the table: 1.
Take care not to damage the table. If needed, you can download a full-scale template from our Web site Kramer Electronics is not responsible for any damage caused to the table 5.2 Adjusting the Height of the Connecting Surface If needed, you can adjust the connecting surface to one of four possible heights to accommodate large or bulky cables.
1. Unscrew the two screws that fasten the power module to the connecting surface, keep the screws, and remove the power module from below. 2. Place and align the Kramer insert under the opening, insert the two screws to fix the Kramer insert in place, and tighten them.
2. Secure the cables to the tie holes using the included self-locking ties. Do not secure the cables too tightly or too loosely. Leave a small amount of slack. After the unit is connected to mains power and the proper cables, TBUS-6 is ready for use. Figure 7: Connecting the Cables...
Technical Specifications Technical Specifications TBUS-6 technical specifications are shown in Table 3: Table 3: Technical Specifications of TBUS-6 2, 3, 4 POWER SOURCE Universal 100-240V AC, 50/60Hz, 5A (AC power limits): 100-240V AC, 50/60Hz, 5A 100-240V AC, 50/60Hz, 5A Germany and EU...
Page 14
For the latest information on our products and a list of Kramer distributors, visit our Web site: www.kramerelectronics.com where updates to this user manual may be found. We welcome your questions, comments and feedback. Safety Warning: Disconnect the unit from the power supply before opening/servicing.