15

ELECTRICAL SYSTEM

15.1
Removing the battery
Warning
Risk of injury Battery acid and battery gases cause serious chemical burns.
Keep batteries out of the reach of children.
Wear suitable protective clothing and goggles.
Avoid contact with battery acid and battery gases.
Keep sparks and open flames away from the battery. Only charge in well-ventilated rooms.
In the event of skin contact, rinse with large amounts of water. If battery acid gets in the eyes, rinse with water for at least 15
minutes and contact a physician.
15.2
Installing the battery
(All TE 250/300)
Preparatory work
Switch off all power consumers and switch off the engine.
Remove the seat. (
Main work
Pull back the negative terminal cover
battery.
Pull back the positive terminal cover
battery.
Detach rubber band
Lift the battery up and out.
M00429-10
(All TE 250/300)
Main work
Insert the battery with the terminals facing forward into the battery compartment.
Battery (YTX5L-BS)
Attach rubber band
Info
Contact disk
with the claws facing down.
Position the positive cable and mount and tighten the screw.
Guideline
Screw, battery terminal
Slide positive terminal cover
Position the negative cable and mount and tighten the screw.
Guideline
Screw, battery terminal
Slide negative terminal cover
M00430-10
Finishing work
Mount the seat. (
p. 52)
and disconnect the negative cable from the
and disconnect the positive cable from the
at the bottom.
.
must be mounted between screw
M5
over the positive terminal.
M5
over the negative terminal.
p. 52)
81
and cable lug
2.5 Nm (1.84 lbf ft)
2.5 Nm (1.84 lbf ft)