Test Transmission; Transmission Delay; Fire, Auxiliary And Panic Keys; Arming/Disarming Options - DSC Power632 DSCPC1555RKW Installation Manual

Table of Contents

Advertisement

If Fire Bell Continuous is enabled, the alarm output will
sound until a code is entered. If disabled, the alarm will sound
until a code is entered or the bell cut-off time has expired.
Bell Cut-off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [005]
Bell Circuit Trouble Reporting Code . . . . . . . . . Section [349]
Bell Circuit Trouble Restoral Reporting Code . . Section [350]
Temporal Three Fire Signal Enable/Disable Section [013]: [8]
Fire Bell Continuous . . . . . . . . . . . . . . . . . . Section [014]: [8]

5.14 Test Transmission

To ensure that the communication link with the central station
is functioning properly, program the panel to send a test trans-
mission signal on a regular basis.
The panel can send a Periodic Test Transmission reporting
code at the programmed Test Transmission Time of Day.
The Test Transmission Cycle determines the period of time
between tests.
NOTE: The LINKS Test Transmission can only be programmed
in days.
If you program the test transmission cycle for a longer period
of time than it was programmed for previously, the system will
wait the original time period before the next test transmission
is sent, and then begin reporting with the new interval.
The panel can also send a test for the LINKS1000 cellular
communicator, if used. If the LINKS1000 Test Transmission
Code is programmed, the panel will send a cellular test at the
interval programmed in the LINKS Test Transmission Cycle.
Users can also generate a communicator test. If the System
Test Reporting Code is programmed, the panel will send the
signal when the System Test keypad command is entered.
(see "[*][6] User Functions" )
Test Transmission Reporting Codes . . . . . . . . . Section [352]
Test Transmission Time of Day . . . . . . . . . . . . . Section [371]
Test Transmission Cycles . . . . . . . . . . . . . . . . . Section [370]

5.15 Transmission Delay

If the transmission delay zone attribute is selected for a given
zone, the panel will delay reporting an alarm for that zone for
the number of seconds programmed for the Transmission
Delay Time. If the panel is disarmed before the delay time
expires, the panel will not report the event.
Transmission Delay Time. . . . . . . . . . . . . . . . . . Section [370]

5.16 Fire, Auxiliary and Panic Keys

The emergency keys are available on all keypads. These keys
must be pressed and held for two seconds before they will
activate. This two second delay is designed to help prevent
accidental activation.
If the [F]/
key option is enabled, when the Fire keys are
pressed and held for two seconds the panel will activate the
alarm output following the option programmed in section
[013]: [8] (see section 5.13 "Bell" ). The alarm output will
sound until a code is entered or until the bell cut-off time
expires. Communication of the signal to the central station is
immediate.
24
If the [A]/
key is pressed and held for two seconds, the
keypad will beep three times to verify activation. The panel will
beep the keypad ten times rapidly when a kissoff is received,
to verify communication to the central station.
If the [P]/
key is pressed and held for two seconds, the panel
will immediately communicate the signal to central station.
If [P] Key Audible Bell and Buzzer option is enabled, when a
user presses the [P]/
key, the keypad will beep three times
and the panel will activate the alarm output until an access code
is entered or the bell cut-off expires. If the option is disabled, the
Panic alarm will be completely silent.
Each LCD keypad can be programmed to have the [F], [A], &
[P] keys enabled or disabled. Please refer to Appendix B: "Pro-
gramming LCD Keypads" .
NOTE: The Fire, Auxiliary, Panic keys will operate even if Key-
pad Blanking is active (see 5.22"Keypad Blanking" )
[F] Key Enable . . . . . . . . . . . . . . . . . . . . . . Section [015]: [1]
[P] Key Audible Bell and Buzzer . . . . . . . . Section [015]: [2]

5.17 Arming/Disarming Options

If the Quick Arm option is enabled, the panel can be armed
without an access code by entering [*][0] or by pressing the
Stay or Away function key. If the Quick Arm option is dis-
abled, users will need to enter an access code after pressing
a function key.
The Quick Exit option, if enabled, will allow someone to leave
an armed premises through a Delay type zone without having
to disarm and re-arm the system. see "[*][0] Quick Exit"
Enable the Arm/Disarm Bell Squawk option to have the
panel squawk the alarm output once upon arming and twice
upon disarming. If an alarm is in memory, when the panel is
disarmed the bell will sound three pairs of disarm squawks.
NOTE: If you enable the Bell Squawk on Arming/Disarming
(section [014], option [1]), the bell will sound arm/disarm bell
squawks for all access codes, regardless of the programming
for attribute [7]. see "[*][5] Programming Access Codes"
Enable both the Squawk on Away Arming/Disarming Only
and the Arm/Disarm Bell Squawk options to have the panel
squawk the bell only when the system is Away armed or dis-
armed.
The Opening After Alarm Keypad Ringback option will
cause the keypad to beep 8 times rapidly after the Opening
After Alarm reporting code has been successfully transmitted
to the central station. The Opening After Alarm Bell Ring-
back option will cause the panel to squawk the bell 8 times
rapidly after the Opening After Alarm reporting code has been
successfully transmitted to the central station.
NOTE: If the panel is armed using the Stay function key, or by
entering [*][9][access code], there will be no bell squawks dur-
ing entry and exit delays, except for the arm/disarm bell
squawks.
Closing Confirmation, if enabled, will cause the keypad to
beep 8 times rapidly after the closing reporting code has
been successfully transmitted to central station.
If the Bypass Status Displayed While Armed option is cho-
sen, the Bypass light will be ON while the system is armed to
indicate that there are bypassed zones.