Light on= Only the buzzer will sound during auto-arm
(see auto-arm, [Q]+[6]+[Master Code]+[2])
[2] Light off= Any key will abort the auto-arm
Light on= Only an access code will abort the auto-arm
(see auto-arm, [Q]+[6]+[Master Code]+[2])
[3] Light off= Keypad LEDs always active
Light on= Keypad LEDs turn off after two minutes of no
key entry. Any alarm, entry delay or key press
will reactivate LEDs.
Note: This feature must not be used with an LCD
keypad.
[4] Light off= Keypad buzzer audible indication of panic
Light on= Keypad no buzzer on panic alarm
(see Keypad Zones, page 11)
[5] Light off= Keypad fire key enabled
Light on= Keypad fire key disabled
[6] Light off= Quick exit disabled
Light on= Quick exit enabled
(see Quick Exit, page 11)
[7] Light off= Answering machine over-ride timer is 60
seconds
Light on= Answering machine over-ride timer is 120
seconds
(See Downloading and Answering Machine, page 14)
[8] Light off= Disable bell shutdown
Light on= Enable bell shutdown
(Any zone that goes into alarm will only trigger one bell
output per alarm. The 'Restorals on Disarming' feature is
recommended to be used with this feature.)

[52] Delay Before Transmission

Program the same as section [22]. This section defines how
long in seconds a burglary zone will wait before transmitting
an alarm. The fire zone and 24 hour zones do not have a
delay. The time may be programmed from 00 to 99 seconds
where 00 means no delay. If the system is disarmed before
the delay in transmission expires, no transmission will take
place.

[53] Auto-arm Abort Reporting Code

This code is programmed the same as section [50]. Once a
reporting code has been programmed into this section, it will
be transmitted any time an auto-arm is aborted to inform the
station that auto-arm has been aborted for that day.

[54] System Test Reporting Code

This code is programmed the same as section [50]. Once
this section is programmed, the code will be sent every time
a bell test is done ([Q]+[6]+[Master Code]+[8]).

[90] Installer's Lockout Enable

This feature is enabled by entering [90] while in the
Installer's Programming mode. A factory default (hardware
or software) will not reset the Installer's Code or the
download access code once this feature is enabled. A panel
that has this lockout feature enabled will give a distinctive
audible indication upon power up. This indication is the
phone line relay clicking ten times. Make sure that your new
Installer's Code has been entered correctly before enabling
this feature because there is no way of re-entering the
programming mode without the new Installer's Code. Even a
reset to the factory default will not change the Installer's
Code back to default.

[91] Installer's Lockout Disable

Entering [91] when in the Installer's Programming mode will
disable the Installer's Lockout feature.
Note: Panels returned to DSC with the Installer's
Lockout feature enabled and no other apparent
problems will be subject to an additional service
charge.