Auto-Arm Cancel Reporting Code; System Test Reporting Code; Tlm Trouble Reporting Code; Links Test Transmission Reporting Code - DSC PC3000 Installation Manual

Hide thumbs Also See for PC3000:
Table of Contents

Advertisement

[53] Auto-arm Cancel Reporting Code

This code is programmed the same as section [50]. Once a
reporting code has been programmed into this section, it will
be transmitted any time an auto-arm is cancelled to inform
the station that auto-arm has been cancelled for that day.

[54] System Test Reporting Code

This code is programmed the same as section [50]. Once
this section is programmed, the code will be sent every time
a bell test is done ([ ]+[6]+[Master Code]+[8]).

[55] TLM Trouble Reporting Code

This reporting code can be transmitted to the monitoring
station through a LINKS 1000 Cellular Alarm Transmitter,
when a TLM trouble occurs on the regular phone lines.
Leave this section blank if there is no LINKS unit connected.
See section [05] for programming reporting codes and
"Trouble Display [ ]+[2]" for a description of TLM trouble.
[56] LINKS Test Transmission Reporting
Code
This reporting code is transmitted to the monitoring station
through a LINKS 1000 Cellular Alarm Transmitter periodically
for testing the cellular communications. The cellular test
transmission occurs at the same time as the regular test
transmission. The test transmission time is programmed in
sections [22] and [23]. After the cellular test transmission is
completed, the periodic test transmission reporting code
programmed in section [15] will be transmitted through the
regular phone lines.
LINKS 1000 Preamble Codes
They are 4-digit codes used with long distance telephone
numbers that are dialled through the LINKS module. These
codes are used for programming area codes in cases where
a land line telephone number may be a local call, while the
cellular telephone number dialled by the LINKS 1000 module
is a long distance call.
In the following sections [57], [58] and [59], program 4-digit
Preambles for the Phone Numbers. Program all unused
digits with hexadecimal "F".
[57] LINKS 1000 Preamble for
1st Phone Number
[58] LINKS 1000 Preamble for
2nd Phone Number
WWW.DIYALARMFORUM.COM
[59] LINKS 1000 Preamble for
Downloading Phone Number
[60] 6th System Option Code
[1] PGM Squawk on Exit Options
ON = PGM Squawk on Exit Delay.
The PGM output will pulse during the Exit Delay Time. If
the Urgency on Exit Delay function described below is
enabled, the PGM pulse will be quickened for the last 10
seconds of the Exit Delay.
OFF = No PGM Squawk on Exit Delay.
Note: Option C must be selected for the PGM output
in section [28].
[2] PGM Squawk on Entry Options
ON = PGM Squawk on Entry Delay.
The PGM output will pulse during the Entry Delay Time.
If the Urgency on Entry Delay function described below
is enabled, the PGM pulse will be quickened for the last
10 seconds of the Entry Delay.
OFF = No PGM Squawk on Entry Delay.
Note: Option C must be selected for the PGM output
in section [28].
[3] Audible Exit Fault Enabled / Disabled
ON = Audible Exit Fault Enabled.
If a Delay Zone is left open at the end of the Exit Delay,
the Entry Delay will begin immediately and the bell or
siren will sound a steady alarm. This feature is designed
to immediately alert the user that their system has been
armed incorrectly.
OFF = Audible Exit Fault Disabled.
If a Delay Zone is left open at the end of the Exit Delay,
the Entry Delay will begin immediately. If the system is
not disarmed before the end of the Entry Delay, an alarm
will be generated.
[4] Exit Delay Urgency Tone Option
ON = Exit Delay Urgency Tone Enabled.
The Keypad will sound a pulsing tone during the Exit
Delay. During the last 10 seconds of the Exit Delay, the
keypad will sound a faster pulsing tone to warn that the
Exit Delay is about to expire.
OFF = Normal Exit Delay Tone.
The Keypad will sound a pulsed tone throughout the Exit
Delay time.
[5] Entry Delay Urgency Tone Option
ON = Entry Delay Urgency Tone Enabled.
The Keypad will sound a steady tone during the Entry
Delay. During the last 10 seconds of the Entry Delay, the
keypad will sound a pulsing tone to warn that the Entry
Delay is about to expire.
OFF = Normal Entry Delay Tone.
The Keypad will sound a steady tone throughout the
Entry Delay time.