Item
4W OUTPUT LEVEL
RTS INPUT LEVEL
RTS OUTPUT LEVEL
RTS CANCEL LEVEL
CLRCOM INPUT LEVEL
CLRCOM OUTPUT LEVEL
CLRCOM CANCEL LEVEL
RTS/CLRCOM LOAD
*1: The default setting varies depending on adjustment at the factory.
PGM
This is the selection screen for the PGM menu.
Item
PGM1 GAIN
PGM1 LEVEL
PGM2 GAIN
PGM2 LEVEL
Setting value
-40dB to 0dB to +20dB
(1dB Step)
-40dB to 0dB to +20dB
(1dB Step)
-40dB to 0dB to +20dB
(1dB Step)
1
-20.0dB to +20.0dB *
(1dB Step)
-20dB to 0dB to +20dB
-40dB to 0dB to +20dB
1
-20dB to +20dB *
ON
OFF
PGM
PGM1 GAIN 
PGM1 LEVEL 
PGM2 GAIN 
PGM2 LEVEL 
Setting value
0dB
20dB
-40dB to 0dB to +20dB
0dB
20dB
-40dB to 0dB to +20dB
Setting details
Switch the 4W (intercom 2) output level.
Switch the RTS (intercom 2) input level.
Switch the RTS (intercom 2) output level.
Switch the RTS (intercom 2) I/O cancellation level.
Set the clear-com (intercom 2) input volume.
Set the clear-com (intercom 2) output volume.
Adjust the clear-com (intercom 2) I/O cancellation signal level.
Switch ON or OFF for the intercom 2 RTS/CLRCOM 200 Ω load.
0dB
0dB
0dB
0dB
Switch the PGM1 input gain.
Set the PGM1 input volume.
Switch the PGM2 input gain.
Set the PGM2 input volume.