Download Print this page

Panasonic AK-UCU500P Operating Instructions Manual page 107

Camera control unit

Advertisement

Item
Transmission type
Unicast port (Image)
Multicast address
Setting value
Unicast port (AUTO)
Unicast port (MANUAL)
Multicast port
1024 to 50000
224.0.0.0 to 239.255.255.255
- 107 -
Setting details
Set the transmission format for H.264 images.
Unicast port (AUTO)
Up to 14 users can access a single camera at the same time.
[Unicast port1 (Image)] will be configured automatically when
images are sent from the camera.
We recommend selecting the [Unicast port (AUTO)] setting
when the port number transmitting the H.264 images does not
need to be fixed (e.g., during use within a network).
Unicast port (MANUAL)
Up to 14 users can access a single camera at the same time.
[Unicast port1 (Image)] must be configured manually when
images are sent from the camera.
When transmitting H.264 images via the Internet, configure a
fixed transmission port number for the broadband router (here-
after referred to as "router").
"HTTP port" (see page 111)
For details, refer to the operating instructions for the router.
Multicast port
An unlimited number of users can access a single camera at the
same time.
When transmitting H.264 images via multicast, enter the [Mult-
icast address], [Multicast port], and [Multicast TTL/HOPLimit].
When transmitting H.264 images via multicast, use a multicast-
compatible router, and specify the transmission destination. In
such cases, configure settings so that H.264 images are not
transmitted to other connected devices (e.g., AK-HRP1000). IP
communication with the camera may be disabled if you transmit
H.264 images to the AK-HRP1000.
Maximum number of simultaneous accesses
Up to 14 users (consisting of users receiving H.264 images and
users receiving JPEG images) can access the unit at the same
time. However, depending on the settings for the [Bandwidth
control (bit rate)] and [Max bit rate (per client)], the number of
users who can access the unit may be limited to less than 14. A
message indicating the access limit will appear if the number of
users exceeds 14. When [Transmission type] is set to [Multicast
port] for [H.264], the second and subsequent users receiving
H.264 images will not be counted toward the total access
count.
Set the unicast port number (used when sending images from the
unit).
This needs to be set when [Transmission type] is set to [Unicast
port(MANUAL)].
Factory settings
H.264 (1) : 32004
H.264 (2) : 32014
H.264 (3) : 32024
H.264 (4) : 32034
Only even numbers can be specified.
The port number cannot be set to 10670 and 49152.
Set the multicast IP address.
Images will be sent to the specified IP address.
This needs to be set when [Transmission type] is set to [Multicast
port].
Factory settings
H.264 (1) : 239.192.0.20
H.264 (2) : 239.192.0.21
H.264 (3) : 239.192.0.22
H.264 (4) : 239.192.0.23
Verify the usable multicast IP addresses before setting
this.