Changing The Hose - Bredel 40-100 Operating Manual

Table of Contents

Advertisement

See also
Refer to "Lubricant table pump" on page 94
7.
Connect the pump to the electrical supply.
8.
Switch on the electrical supply.
8.7

Changing the hose

Removing the hose
1.
Isolate the pump from the electrical supply.
2.
Close any shut-off valves in the suction and discharge line to minimise the loss of process fluid.
A
B
Note: The drain plug is in the bottom of the pumphead.
3.
Place a tray (A) under the drain plug. The tray must be large enough to contain the lubricant,
possibly contaminated with product fluid, from the pumphead. Remove the drain plug (B).
Collect the lubricant from the pump housing in the tray.
4.
Check the sealing ring (C) is not damaged and replace it if necessary.
A
B
5.
Check that the breather vent mounted on the rear is not obscured.
6.
Position the drain plug and tighten it to the specified torque.
m-bredel-40-100-en-05
C
C