4.4

Pump installation positions

The pump can be delivered with the following possible pumphead installation positions:
Position
1
Pump ports at left hand side when facing the pump at the cover.
2
Pump ports at right hand side when facing the pump at the cover.
3
Pump ports facing upwards.
4
Pump ports facing downwards.
Concerning pumps Bredel 40, Bredel 50, Bredel 65, Bredel 80, and Bredel 100 the inspection window
always resides between the inlet and the outlet port. An accurate reading of the lubricant level
through the inspection window is only possible at pump positions 1 and 2. An accurate reading of the
lubricant level through the inspection window is not possible at pumps in pump positions 3 and 4
At every pump position, operational rotation of the rotor is possible in both directions. In this manual
the illustrations are based on pumphead position 2.
24
Description
Pump layout