14.4
Changing main fuse
Warning
Fire hazard Incorrect fuses overload the electrical system.
–
Only use fuses with the required ampere value.
–
Do not bypass or repair fuses.
Main work
–
Check the battery voltage.
»
Battery voltage: < 9 V
–
Do not charge the 12 V battery.
–
Replace the 12 V battery and dispose of the old 12 V
battery properly.
»
If the specifications have been met:
Battery voltage: ≥ 9 V
–
Charge the 12-V battery.
S00863-10
Guideline
The charging current, charging voltage, and charging
time must not be exceeded.
Maximum charging volt-
age
Maximum charging cur-
rent
Maximum charging time
Recharge the 12-V bat-
tery regularly when the
motorcycle is not being
used
Battery charger (79629974000)
This battery charger tests whether the 12-V battery
retains its voltage. It is also impossible to overcharge
the 12-V battery with this battery charger. The charging
time may be longer at low temperatures.
This battery charger is only suitable for lithium iron
phosphate batteries. Read the accompanying KTM Pow-
erParts instructions.
–
Switch off the battery charger after charging and disconnect it
from the 12-V battery.
Finishing work
–
Install the 12 V battery.
–
Mount the seat. (
ELECTRICAL SYSTEM 14
14.4 V
3.0 A
24 h
6 months
Info
1
Never remove cover
.
(
p. 97)
p. 59)