Technical Data
Fig. 4
Residual Risks
Despite all mechanical and electrical protective means the appliance is equipped
with according to the regulations (both in the operational phase and during cleaning
and maintenance), residual risks exist that cannot be completely precluded. In this
instruction manual they are indicated by the warning word WARNING. Observe also
warning indications on warning stickers placed on the appliance.
Residual risks (e.g., danger of injury) may be present also when slicing smaller
pieces or pushing residues. To this end, the appliance is equipped with the pusher
handle with pusher.
After disassembly of the appliance for cleaning, pay particular attention to the blade,
as with the sharpener removed, part of the blade is exposed.
174196
15
Sharpener serving as the upper
blade guard
There is a magnetic connector (a) on the
sharpening tool: the appliance operates
only when the sharpener is properly
positioned.
When the sharpener is removed during
operation the appliance stops. Once the
sharpener is properly repositioned the
appliance does not start automatically but
it needs to be switched on again with the
white START button in the ON/OFF switch
(B, Fig. 7).