CITY
BOMBAY
(*) Paris and the following cities: Frankfurt, Madrid, Stockholm, Oslo, Zurich, Milan,
Amsterdam, etc.
(**) SINGAPORE, and the following cities: Taipei, Bangkok, Hong-Kong, Kuala Lumpur,
Beijing, etc.
VII - TECHNICIAN MENU
Access to the technician menu is via the two push buttons [SELECT] and [+] located on the
back of the clock. The [SELECT] button is above the [+] button.
Proceed in two stages.
1. Press the [SELECT] button, and while holding it down, press [+] for more than 3 seconds
to go initially to Configuration menu.
2. Press the [SELECT] button, and while holding it down, press [+] for
more than 7 seconds to go to Technician menu. The programme version
for the clock is displayed.
3. Press the [SELECT] button to display the menu for the type of synchronisation. The [+]
button enables you to choose between Ind and Sync (if the synchro
card is connected) or Ind, DHF and DHFi.
Ind : autonomous mode (deactivates pulse/coded time
reception card).
Sync : activation of the radio synchronisation card or coded
time/impulse reception.
DHF: activation of the DHF synchronisation card. After 24
hours without signal, the clock stops.
DHFi : activation of the DHF synchronisation card. After 24
hours without signal, the clock keeps on working on its own time basis.
The default configuration of the DHF receiver clock is DHFi.
4. Press [SELECT], according to the clock's option and the previous selection :
Ind : the programme of the clock go directly to the step "Test display".
Sync (radio) : The Radio Reception menu is displayed. The
radio pictogram flashes to indicate that the search is under
way. The display shows the construction of the time
32
Zone
Reference zone
GMT
No Change
Time difference/GMT
+5.30