Radio Synchronised Clock; Afnor Or Impulses Slave Clock; Dhf Clock - Bodet Cristalys 7 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

b
Press [+] until the required month is displayed.
5. a
Press [SEL] to validate the month : the day flashes.
b
Press [+] until the chosen day is displayed (Scrolling of the days
takes account of the month and year selected (leap years)).
6. a
To conclude time setting, press the [SEL] button.
Caution : At any time by holding down [SEL] then, pressing [+] quickly, will return you to
normal display mode.
If no buttons are pressed for a period of over 10 minutes, the clock automatically returns to
normal time display mode.

4.2 Radio synchronised Clock

If the quality of reception is good, the time on the clock will be set automatically. In zones
where the radio signal is difficult to receive, clock can be set on time manually, following the
procedure described in the previous chapter.

4.3 AFNOR or impulses slave Clock

The time on the AFNOR/Irig-b slave clock will be set automatically.
After a reset or a time setting, the clock search each minute, during 20 seconds, until it get
synchronised.
Minute or ½ minute slave clocks must be set to the time of time distribution network.
Remark : See the chapter "Technician Menu" page 32 to parameter to time distribution.
Caution : In case of no AFNOR synchronisation message :
After setting up or after changing the batteries, the time will not be running and the
clock will only display two points.
It is always possible to modify the time setting but the time will not be running and the
cock will only display the two points.

4.4 DHF clock

Caution: when installing the clock, the master clock Sigma or the transmitter must be set to
INIT mode.
DHF clocks are self-setting clocks.
After inserting the batteries, the clock displays INIT for 5 seconds then 00:00.
The synchronisation search is limited to 4 hours. Beyond, the clock stops searching
and displays only 2 fixed dots. A press on one of the keys will restart the
synchronisation search for 4 hours.
It memorises the address of the transmitter and switches to normal mode
automatically when time is received.
25

Advertisement

Table of Contents
loading

Table of Contents