Wire Rope - HADEF 238/10-EX Installation, Operating And Maintenance Instruction

Manual worm gear wire rope winch
Table of Contents

Advertisement

Make sure that no fat gets on the load pressure brake (A).
Install the protection plate again.
NOTICE!
To ensure correct functioning of the load pressure brake, the winch must be loaded with at least 5 % of the
nominal load.
8.3

Wire rope

Wire ropes must be free from corrosion, dirt or damage.
They must be lubricated before commissioning.
No lubrication shortens the lifetime of the wire rope and the maintenance intervals.
WARNING!
It is not allowed to use plastic wire ropes or plastic-coated wire ropes.
9
Safety check
Before putting into service initially or when putting back into service, it must be checked whether:
 All fastening screws (if existent), socket pins, flap socket and safety devices are tightened and secured.
 The wire ropes are winded up correctly, are lubricated and are in good condition.
10
Functional test
The functional test must be effected with the load capacity mentioned on the type plate.
Check the brake when lifting/lowering - it must hold the load safely.
Check the condition of the wire rope and the supporting structures.
Check screw connections.
11
Maintenance
11.1
General
All monitoring, servicing and maintenance operations are to ensure correct functioning of the equipment;
they must be effected with utmost care.
 Only "qualified persons" may do this work.
 Servicing and maintenance work must only be done when the hoist is not loaded.
 Records must be kept of all test results and measures taken.
11.2
Monitoring
The monitoring and servicing intervals stated are valid for operation under normal conditions and single-shift
operation. In case of severe operating conditions (e.g. frequent operation with full load) or special
environmental conditions (e.g., heat, dust, etc.), the intervals must be shortened correspondingly
12
Inspection
12.1
Periodic checks
Independently from the regulations of the individual countries, lifting devices must be checked at least yearly
by a qualified person or licensed qualified person regarding its functional safety.