6021/6031 Series (Push Side) Power Operator

Install Operator

A. Secure Backplate.
1. Secure backplate to frame using six (6):
1/4-20 x 5/8" machine screws or
1/4 x 1-1/2" self-drilling screws. (Figure 7)
NOTE: It is important to properly secure
top edge of backplate. Use of blocking
(supplied by others) or shims (provided) to
fill gap between backplate and wall above
header is HIGHLY recommended. Material
must comply with local codes. Failure to
properly secure top of backplate could result
OR
in operator being allowed to 'rock' during
operation. This could result in damage to
operator and diminish operator function.
(Figure 7)
B. Install End Caps.
1. Secure end caps to each end of backplate
using four (4) (two each) #8-32 x 5/16" Phillips
pan head screws. (Figure 8)
NOTE: Orient end caps so that text on labels
is legible when observed from ground.