SETUP functions (6)
The unit is equipped with a number of additional functions that can be selected. Parameters can
be set via the SETUP function. The SETUP function is activated by pressing the SETUP button
(6) for >1 second. The adjustable parameter is selected via the left-hand potentiometer (2), the
name of which is shown on display No. 4. The value of the parameter in question is adjusted via
the right-hand potentiometer (3), the value of which is shown on the display (5). The parameters
and their possible values are:
Name of
Name on
parameter
display
Creep Start
Cre
Hot Start
hot
Crater Level
Crl
Post Current
PoC
Calibration
Cal
Voltage
1-MIG Unit
uni
mm, m/min
Selection of
add
Wire Feeder
Address
Maximum
fs
Wire Feed
Speed
Disable PMT
gun
MIG guns
Restore
faC
Factory
Settings
SETuP-
The value of the parameter is immediately recorded in the memory. Exit SETUP mode by holding
down the new SETUP button or by briefly pressing the ON/OFF button.
© Kemppi oy
Parameter
Factory
values
setting
10 ... 170 %
50 %
-50 ... +70 %
40 %
5 ... 99%
50 %
-9... +9
0
-5,0 ... 9,0 V
0,0 V
m/min or mm
m/min
or a
85 or 90
85
18 or 25
18 m/min
m/min
off or on
on
off or on
off
Description
Percentage of wire feed speed:
10 % slowed start
170 % accelerated start
Percentage of welding power:
-50 % cold and
+70 % hot
end level of welding power,
5 % = minimum current,
99 % = maximum current
Post current
Compensation (1-mig)
in 1-mig welding, parameter
unit shown in left-hand display/
average current
wire feeder address
the max. wire feed speed selected;
dependent on feed wheels
off = other gun
on = Pmt gun
restores factory settings when 'on'
is selected, exit setuP mode
WeldForce KWF 500, 300, 00S, 300S / 061 – 1