Memory functions (16, 17, 18)
Storage of settings
The memory functions can be used to record useful welding values in the memory. There are ten
different memory locations: 0 ... 9.
In addition to welding values (wire feed speed, welding voltage), function options such as 2T/4T,
Creep Start, and Crater Level are recorded in the memory.
Storage in memory is performed as follows:
1. Press the MEMORY button twice; the SET light begins to flash if the channel is not in
use. If the channel is in use, the light remains lit. N.B.! If the memory is empty, press the
MEMORY key once to get in SET mode.
2. Select the desired memory channel with the CH key.
3. Make the settings and store them in the memory by pressing the SAVE button.
4. Press the MEMORY key twice. Notice that the ON light is lit.
5. Begin welding.
If you wish to change some values, the light must be switched from the ON setting to the SET setting
to enable you to select the required parameters. Press the SAVE button to complete the procedure.
It is also possible to save the parameters of the current weld by pressing SET when the memory
function is in OFF status (all lights off). The channel can be cleared by pressing MEMORY and
the CH button simultaneously in SET mode.
Use of stored settings
1. Press the MEMORY button.
2. Select the memory channel via the CH button.
3. Begin welding.
The Ch remote function enables selection of memory channels via the selection controller located
on the gun. The function is activated by pressing buttons 10 and 17 simultaneously. When the CH-
remote is activated the light in remote control or in gun control starts to flash.
Synergic 1-MIG welding (14, 19)
In Synergic 1-MIG welding, the optimal welding parameters for the welding wires and gas used are
recorded in the unit. The welding is controlled by adjusting the welding power and arc length.
Welding arc/programme selection:
Before commencing welding, a welding arc/programme suited to the welding wire and gas used
must be chosen from the sticker glued to the inner surface of the KWF door.
Arc selection is activated by pressing button No. 19 for >1 second. In this case, displays 4 and 5
begin to flash and the material group is selected from the left-hand potentiometer and the welding
arc/programme for the material group in question from the right potentiometer; see the enclosed
table. (The table is also included on a sticker on the wire feed unit.)
© Kemppi oy
Parameter
Factory
values
setting
10 ... 170 %
50 %
-50 ... +70 %
40 %
5 ... 99 %
50 %
Description
Percentage of wire feed speed:
10 % on hidastettu aloitus,
170 % on kiihdytetty aloitus
Prosenttia hitsaustehosta:
-50 % slowed start,
+70 % accelerated start
welding power end level,
5 % = minimum current,
99 % = maximum current