10.2.4 Set Region Exiting Detection

It is used to detect objects exiting from a predefined virtual region. If it occurs, the device can take
linkage actions.
Steps
1. Go to VCA → Smart Event → Region Exiting Detection .
2. Select Channel No..
3. Check Enable.
4. Click Add to add a rule and set a detection area.
1) Draw a detection area. Click
boundaries of the detection area, and right click to complete drawing.
2) Optional: Click
5. Set parameters.
Sensitivity
It stands for the percentage of the body part of an acceptable target that goes across the
predefined region. Sensitivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
across the predefined region. ST stands for the complete target body. The higher the value of
sensitivity is, the more easily the alarm can be triggered.
6. Optional: You can set the parameters of multiple areas by repeating the above steps.
7. For the arming schedule settings, refer to Set Arming Schedule . For the linkage method settings,
refer to Linkage Method Settings .
8. Click Save.

10.2.5 Set Unattended Baggage Detection

It is used to detect the objects left over in the predefined region. Linkage methods can be triggered
after the object is left and stays in the region for a set time period.
Steps
1. Go to VCA → Smart Event → Unattended Baggage Detection .
2. Select Channel No..
3. Check Enable.
4. Click Add to add a rule and set a detection area.
1) Draw a detection area. Click
boundaries of the detection area, and right click to complete drawing.
2) Optional: Click
5. Set parameters.
Sensitivity
Sensitivity stands for the percentage of the body part of an acceptable target that enters the
predefined region. Sensitivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
Network Camera User Manual
, click on the live view to specify the vertexes and draw the
to delete all the setting areas.
, click on the live view to specify the vertexes and draw the
to delete all the setting areas.
79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds-2cd6d44g1-izs

Table of Contents