Craftsman 258.1240100 Installation Manual page 15

With grill lighting instructions
Table of Contents

Advertisement

A,
B.
CAUTION
After purging or filling an L.P.Gascylinder,DONOT inserta
POL plug into the valve outlet. Insertionof theplug will prevent
the back-checkfrom closing.Use ONLYthe providedcapand
strap attachedto the outlet. Closethe cylindervalveknob
beforereturningthe cylinderto the customer.
For properpurging proceduresreferto:
t
In the US: Safety BulletinNPGA#133,"PurgingL.P.Gas
i
Cylinders",and Safety BulletinNPGA#130,"Recommended
i
Proceduresfor FillingCylinders".
f
Hose end valve with a bleedport (Fig. 13):
Purgingcan be accomplishedusinga hoseend valve containing
a bleed port which also allowsfor evacuationwithoutthe use of
an adapter.
Hose end valve without a bleedport:.
When a hose end valve doesnot havea bleed port, a separate
device must be used for evacuation.
i
¢.
Purgingusinga Type 1 connection(Fig. 14):
L.E Gas cylinderevacuationcan be accomplished duringeach
purgingby usinga Type 1 connection. The Type1 valveoutlet
hasan external1 5/16"ACME right handthreadwhichwill
acceptthis connection.
DtSPOSITiFS
DE PURGE
ET D'EVACUATION
PQUR I. FS ROUTE{LLES
AVEC
VALVES DE TYPE
f:
]
ATTENTION
Apr_savoirpurg_ou rempliunebouteille de GPL,NE PAS insurerde
bouchonPOLdansI'orilfce de sorUe de la valve. L 'insertion d u bouchon
emp_hera le dispos_fde non-retour d e sefermer. U tiliser
UNIQUEMENT l ecapuchon e tlasangleattaches _ I'orifice de sortie.
Fermer la poign#ede la valvede la bouteille avant d e la redonner
I'uUlisateur.
-.
Pour de plus amples renseignements concemant l es procedures
correctesde purge, consulter:
Aux USA : SafetyBulletinNPGA# 133,"Purging L.R Gas
Cylinders",et Safety BulletinNPGA#130, "Recommended
Proceduresfor Filling Cylinders".
A. Valved'extr#mit6 de tuyauavec port de purge (Fig. 13) i
La purgepeut &trer_alis#e_ I'aided'unevalved'extr#mit#de ; "
tuyaucontenantun port de purge permettant l a d#chargesans
I'utilisationd'un adaptateur.
B. Valved'extr#mit#de tuyau sansport de purge :
Lorsquela valve d'extr6mit_de tuyaufie poss_e pas #e port de
purge,un dispositifs#par6dolt #treutilis6pour la d#charge.
C. Purgeavec raccordde Type 1 (Fig. 14)"
La d#chargedesbouteillesde GPLpeut #trer#alis#edurant
chaquepurge _ I'aided'un raccordde Type1. L'orificede sortie
de valvede Type 1poss#de un pas _ dreiteexterneAcm#de _1
5/16",qui acceptece raccord.
"
PROPANO
LlCUADO
CON VALVULAS
DE TANQUE
DEL TIPO
I
"
CUIDADO
Despu_sde purgar o Ilenarun tanquede propanolicuado,NO
insertarun tap6n POEdentro de la salidade la v&lvula.La
inserci6ndel tap6r_impedir_el cierrede la reienci6n.Usar SOLO
la tapay la corre&c0nectadaa la salida.Cerrarel bot6nde la
v_.lvuladel tanque antes de devolve[el tanqueal cliente.
Para obtenerprocedimientos de purga adecuados, c onsultar:
En el US: Safety Bulletin NPGA#133,"Purgade Tanquesde Gas
de PropanoLicuado",y SafetyBulletinNPGA#130,
"ProcedimientosRecomendados para el Llenadode Tanques ° .
U & C 1142-0161
A. V&lvuladel final de la mangueracon unasalidade escape
(Fig. 13):
La purgase puederealizarusandouna v_lvuladel final de la
mangueraque contengauna salidade escape,que tambi_n
permitela evacuaci6nsin el usode un adaptador.
B. V_lvuladel finalde la mangUera sinuna salidade escape:
Cuandouna v_.lvula de final de manguerano poseeuna salida
de escape,se debe utilizar un dispositivo separadopara la
evacuaci6n.
C. Purgausandouna conexi6ndel Tipo 1 (Fig.14):
La evacuaci6ndel tanquede propanolicuadose puederealizar
durantecadapurga por mediode usaruna conexi6ndel lipo 1.
La salidade vAIvuladel Tipo 1 poseeun roscadohacia la
derecha1 5/16"ACME. q ue aceptar&estaconexi6n.