Details of Parameters
PrNo. Parameter
18
2nd position
loop gain
19
2nd velocity
loop gain
1A
2nd velocity
loop integration
time constant
1B
2nd speed
detection filter
1C
2nd torque filter
time constant
1D
Notch
frequency
1E
Notch width
selection
1F
Disturbance
torque
observer
*1Note that the running noise of the motor becomes larger, with a smaller value of Pr1F
(better suppression of the Disturbance torque). It is recommended that you start from
the smaller value of Pr1F to see the actual response and increase the value.
・For the calculation of Disturbance torque in the observer, the inertia ratio (Pr20) is
necessary. If the load inertia is known, calculate the inertia ratio and set the value of
Pr20 to the inertia ratio calculated. If the load inertia is unknown, perform the auto
gain tuning that automatically enters the value of Pr20.
< Note >
・ For the default values of Pr19, Pr1C and Pr20, see page 44.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Value
Unit
10 〜
1/s
・ This driver provides 2(two) sets (1st. and 2nd.)
2000
【50】
1 〜
Hz
3500
・ The functions and meanings of these 2nd gains
1 〜
ms
1000
【50】
・ For switching between the 1st and 2nd gains
0 〜 5
【4】
* If Pr20 (inertia ratio) has been set correctly, the
0 〜
0.01ms
2500
100 〜
Hz
・ You can set-up the frequency of the resonance suppression notch filter.
1500
・ You can set-up the resonance frequency of the machine system which
【1500】
・ This notch filter function will be disabled by setting this  parameter to
0 〜 4
【2】
0 〜 8
・ You can set-up the time constant (eight options) of the primary
【8】
The smaller the setting is, the larger
the suppression you can expect. *1
− App. 38 −
Function
of gain and time constant for position loop,
velocity loop, velocity detection filter and torque
command filter.
or time constants are the same as those of
the 1st ones mentioned in the previous page.
or constants, see Adjustment.
unit of the values of Pr11 and Pr19 is Hz.
you can obtain by the frequency characteristics analysis program
contained in PANATERM.
1500.
You can set-up the width (five options) of the resonance suppression notch
filter in 5 steps. The higher the setting is, the wider the width you can obtain.
In normal cases, the default value should be used.
delay filter inserted in the Distulbance torque observer.
Value of Pr1F
0 〜 7
8
  
Disturbance torque
observer disabled.