ERRORS & TROUBLESHOOTING

Motor Error2

Occurs when the platen is in motion
and fails to reach the upper or lower
limit position within 30 seconds,
(150 encoder counts)
L1: MOTOR
L2: ERROR2
Audio Alarm
Recycle Main
Power Switch
Page 32
continued

Lower Switch Error

Occurs at cycle start when the
lower limit switch fails to signal the
platen's arrival at the lower limit
position within 200 seconds.
L1: LOWER SWITCH
L2: FAIL
Audio Alarm
Recycle Main
Power Switch

Upper Switch Error

Appears in code,
but is never set.
L1: UPPER SWITCH
L2: FAIL
Audio Alarm
Recycle Main
Power Switch