Connection — Electrical Power
Verify if the technical specification of the appliance (see the rating plate)
corresponds to the characteristics of the local electric mains grid.
The power cord should be laid in a way preventing anyone from threading on it
or tripping against it.
A circuit breaker of sufficient capacity to disconnect all poles from the power
supply must be installed upstream of the appliance, in an easily accessible
place; its contact opening width must ensure complete separation according to
overvoltage category III, in accordance with the installation regulations. The
maximum permissible leakage current of the appliance is 1 mA/kW.
Flexible, oil-resistant rubber hoses type H05RN-F or H07RN-F must be used for
connection. Cord cross-section is stated in the technical data table.
Connect the power cord to the terminal block according to the wiring diagram
supplied with the unit.
Secure the part of the power cord outside the appliance with a metal tube or
rigid plastic hose.
In the event of damage to the power cord, have it repaired by the manufacturer,
service company or a professional to exclude any risk.
EN
Connect the electrical appliance to a working earthing.
Connect the protective conductor to the terminal marked with the earth symbol
next to the input terminal block.
Connect the metal structure of the electrical appliance to a protective
equipotential bonding device.
Connect the conductor to the terminal marked with the equipotential bonding
symbol on the outside of the bottom of the appliance.
This symbol indicates that the appliance must be integrated into the
equipotential bonding system and connected in accordance with applicable
regulations.
Do not use the appliance with an external timer or remote control.