Figure 50d: Handle Disassembly
7. Remove gasket, hook, and hook gasket.
Figure 50e: Handle Disassembly
8. For Cascade Units - remove plug assembly.
Figure 50f: Handle Disassembly
AH-07-01.10
Vector AA90 Applicators - Maintenance
9. For Classic Units - remove resistor tube as-
sembly.
Figure 50g: Handle Disassembly
Apply LSCH0009-00 dielectric grease to resistor
tube prior to reassembly.
Figure 50h: Handle Disassembly
Handle Reassembly
1. Reverse disassembly procedure. Replace parts
as required. Use LSCH0009-00 on all electrical
components.