FILTERS

(CLASSIC AND CASCADE)
Install an air filter assembly onto the factory air.
An air filter MUST be installed to pre-
>
vent contamination of the coating material
by the atomization and fan air.
LINE HOSE - AIR
(CLASSIC AND CASCADE)
Ransburg supplies a standard 2m whip hose with
all applicator assemblies. Connect air hose of
proper size and length based on application.
W A R N I N G
!
† Use only hose rated at 6.9 bar (100 psig)
working pressure or above.
AH-07-01.10
NOTE
Vector AA90 Applicators - Installation
LINE HOSE - FLUID
(CLASSIC AND CASCADE)
Ransburg supplies a standard 1m whip hose.
Optional hose lengths are available. Ransburg
offers this hose ONLY as a complete assembly
to ensure that the hose is properly grounded at
each end fitting.
W A R N I N G
!
† Use only high pressure hose rated at 193
bar (2800 psig) working pressure or above.