Applicator Repair; Equipment Required - Ransburg Vector AA90 Cascade Service Manual

Table of Contents

Advertisement

APPLICATOR REPAIR

All repairs should be made on a clean, flat sur-
face. If a vise is used to hold parts during service
or repair, DO NOT clamp onto plastic parts and
always pad the vise jaws!
Apply dielectric grease (LSCH0009-00) to the
following parts when assembling:
• All O-Rings (PTFE o-rings do not need lu-
brication)
• Needle Shaft Assembly
• Packing Tube
• Resistor Tube Assembly (Classic)
• Air Valve Rod Assembly 79310-00
Apply sealant (7969-10) to the external threads
of the following parts when assembling:
• Air Valve Retaining Nut
AH-07-01.10
Vector AA90 Applicators - Operation

EQUIPMENT REQUIRED

• Special Multi-Purpose Applicator
Wrench 19749-00
• Air Cap Removal Tool 79642-00
• 2.5mm Wrenches 74133-00 (2)
• Nozzle Wrench 76428-00
• 3/32-inch Allen Wrench
• Open End Wrenches: 15/16, 7/8, 11/16,
9/16, 7/16, 3/4, 3/8, and 1/4-inch
• Screwdriver (blade)
• Dielectric Grease LSCH0009-00
• Medium Strength Sealant 7969-10
• Plastic or Wood Dowel Rod, 5/16-inch
diameter
32