Ransburg Vector Solo Product Manual

Separate power module

Advertisement

Quick Links

PRODUCT MANUAL
AH-10-01
Vector Solo SPM
Separate Power Module
MODEL: 80011 Vector Solo SPM
80012 Power Supply Control Unit
IMPORTANT: Before using this equipment,
carefully read SAFETY PRECAUTIONS, starting on
page 1, and all instructions in this manual. Keep
this Service Manual for future reference.
Product Manual Price: $50.00

Advertisement

Table of Contents
loading

Summary of Contents for Ransburg Vector Solo

  • Page 1 PRODUCT MANUAL AH-10-01 Vector Solo SPM Separate Power Module MODEL: 80011 Vector Solo SPM 80012 Power Supply Control Unit IMPORTANT: Before using this equipment, carefully read SAFETY PRECAUTIONS, starting on page 1, and all instructions in this manual. Keep this Service Manual for future reference.
  • Page 2 NOTES...
  • Page 3: Table Of Contents

    Control Unit I/O and Ground Connections Vector Solo SPM Gun Connections Section 4: OPERATION Operation of the Control Unit Section 5: SERVICE Servicing the Vector Solo SPM Gun Section 6: PARTS LIST Vector Solo SPM Gun Parts List Section 7: APPENDIX Warranty Policies...
  • Page 4: Section 1: Safety

    WARNING The user MUST read and be familiar with the Safety Section in this manual and the ITW Ransburg safety literature therein identified. This manual MUST be read and thoroughly understood by ALL personnel who operate , clean or maintain this equipment! Special care should be taken to ensure that the WARNINGS and safety requirements for operating and servicing the equipment are followed.
  • Page 5 If used, a key switch bypass is intended for use only during setup operations. Production should never be done with safety interlocks disabled. Never use equipment for use in waterborne installa- tions to spray solvent based materials. AH-10-01 : Vector Solo SPM...
  • Page 6 Any other type of solvent may be used with aluminum equipment. AH-10-01 : Vector Solo SPM...
  • Page 7 An electrical arc can ignite coating materials Production should never be done with the safety cir- and cause a fire or explosion. cuits disabled. Before turning the high voltage on, make sure no ob- jects are within the sparking distance. AH-10-01 : Vector Solo SPM...
  • Page 8 Comply with appropriate codes governing ventilation, fire protection, operation maintenance, and housekeep- ing. OSHA references are sections 1910.94 and 1910.107. Also refer to NFPA 33, 2009 Edition and your insurance company requirements. AH-10-01 : Vector Solo SPM...
  • Page 9: Section 2: Introduction

    Section 2: INTRODUCTION The Vector Solo SPM (Separate Power Module) system is a specialty design that combines the performance of an elec- trostatic applicator along with the voltage generation of an off unit alternator. By removing the air driven voltage genera- tor from the applicator and installing it into a control unit box, the applicator weight is reduced significantly.
  • Page 10: Specifications

    Minimum Inlet air pressure to control Unit: 8.5 bar (50 psig) Applicator Weight (less Cable): 700 g Maximum Inlet air pressure to control Unit: 7.6 bar (110 psig) Maximum Output Voltage: 45 kV Maximum output voltage: 15.5 volts DC Maximum Output Current: 120µA AH-10-01 : Vector Solo SPM...
  • Page 11: Section 3: Installation

    Appropriately tighten each fitting. Connect the female cable connector to the male connector on the control unit. Male Cable Connection Main Air Into Control Unit Air Out to Applicator Bottom View AH-10-01 : Vector Solo SPM...
  • Page 12: Vector Solo Spm Gun Connections

    Connect the supplied ground line from the control box to a true earth ground as shown in the picture below. WARNING: For the unit to properly function, a true earth ground connection must be made. Ground Connection VECTOR SOLO SPM GUN CONNECTIONS Connect fluid, air and cable to the applicator. Air Inlet to Applicator Fluid Inlet Connection...
  • Page 13: Section 4: Operation

    All color changes must be made in this position. Failure to follow this may cause injury to the operator. All OFF Position / Flush Position The second position is atomization/fan air ON, voltage OFF. Atom / Fan Air ON - VOLTAGE OFF AH-10-01 : Vector Solo SPM...
  • Page 14 The gage on the front panel will indicate the pressure level. Gauge Indicating Atom / Fan Pressure Adjustment Knob: + increases pressure, - decreases pressure AH-10-01 : Vector Solo SPM...
  • Page 15 If conductive polar solvents are used to clean the applicator components, all residue must be removed using a non-conductive non-polar solvent (i.e. high flash Naphtha). If there are any questions as to what solvents are best for cleaning , contact your local ITW Ransburg distributor and/or your paint supplier.
  • Page 16 Applicators may be flushed in lieu of tilting. However, they must be either flushed or tilted down during nozzle removal! • Straighten the applicator electrode if necessary. • Clean the fluid filter, if used. AH-10-01 : Vector Solo SPM...
  • Page 17: Section 6: Parts List

    Section 6: PARTS LIST VECTOR SOLO SPM GUN PARTS AH-10-01 : Vector Solo SPM...
  • Page 18 VECTOR SOLO SPM GUN PARTS AH-10-01 : Vector Solo SPM...
  • Page 19 VECTOR SOLO SPM NEEDLE SHAFT PARTS AH-10-01 : Vector Solo SPM...
  • Page 20: Section 7: Appendix

    EXCLUSIONS: If, in ITW Ransburg's opinion the warranty item in question, or other items damaged by this part was improperly installed, operated or maintained, ITW Ransburg will assume NO responsibility for repair or replacement of the item or items. The purchaser, therefore will assume all responsibility for any cost of repair or replacement and service related costs if appli- cable.
  • Page 21 NOTES AH-10-01 : Vector Solo SPM...
  • Page 22 Technical Support Representatives can direct you to the appropriate telephone number for ordering spare parts. Form No. AA-09-01 © 2010 Illinois Tool Works, Inc. All rights reserved. Litho in U.S.A. Models and specifications subject to change without notice. 10/10 AH-10-01 : Vector Solo SPM...

This manual is also suitable for:

8001180012

Table of Contents