Lighting Procedure
IMPORTANT: The remote control system supplied with this appliance has
several options for starting/operating the appliance using the power button
and ON/OFF key on the hand held transmitter.
Prior to operating this appliance, please read the remote control operating
instructions (packaged with remote control) to understand how to operate
this remote control system.
1. Ensure the Main switch is in the ON position (see diagram on page 9
step 5 for location of switch) and/or the battery holder switch is in the
Remote position.
2. Press and release the ON/OFF button on the remote handheld transmitter
(see Diagram 2). An audible beep should be heard from the receiver.
ON/OFF
Button
Remote shown in Manual Mode on 'Hi'
NOTE: Remote handheld not exactly
as shown
3. After approximately 4 seconds the spark ignition system will spark for 60
seconds to light the main burner.
4. The unit will turn on.
Actual remote is Black
Not silver as shown
60
| RC500E-11
Diagram 2
Note: The first try for ignition will last approximately 60 seconds. If there is no
flame ignition (rectification) the board will stop sparking for approximately
35 seconds. After wait time , the board will start second try for ignition by
sparking for approximately 60 seconds. If there is still no positive ignition
the board will go into lock out.
The system will need to be reset as follows:
a) Wait 5 minutes - turn the system off by pressing the ON/OFF button on
the remote.
b) After approximately 2 seconds turn on ON/OFF switch or press ON/OFF
button if using optional remote.
c) Repeat step 2.
Shutdown Procedure
1. Press the ON/OFF button on the remote
2. If service is to be performed- you must disconnect power and shut off gas
to the unit.
*
*
*
Fan Operation:
The optional fan can be operated by using the remote control supplied with
this unit. See remote control instructions.
Note:
In thermostat mode: When the appliance is turned on, the fan will not come
on for the first 5 minutes (if fan is turned on). When the appliance is turned
off the fan will not turn off for 12 minutes (if in on position)
Manual mode: Fan will turn on and off immediately using the remote control
transmitter if the fan function is in the "on" position.
Continuous Pilot/Intermittent Pilot (CPI/IPI) selection
CPI mode - Pilot is lit and remains lit 24 hours a day. If there is no call for
heat for a period do of 7 days the pilot will shut down. The pilot would need
to relight if you choose to keep pilot lit.
This feature would be used if you are in a cold climate where a good draft
must remain at all times. This also eliminates nuisance start up and moisture
inside of the fireplace.
IPI mode - Pilot is only lit when there is a call for heat. When appliance turns
off pilot will also shut off.
For more info on how to set this up see details in this manual under remote