Owners & Contura RC500E Direct Vent Gas Fireplace ® Installation Manual MODELS: RC500E-NG11 Natural Gas RC500E-LP11 Propane Warning Fire or Explosion Hazard Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Page 2
Congratulations! You are the owner of a state-of-the-art Contura RC500E Gas Stove by REGENCY FIREPLACE PRODUCTS. The RC500E is a ® hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
table of contents Copy of Safety Label ............4 Installation Precautions ............. 25 Unit Dimensions with Vertical Venting ........5 Safety Precautions for the Installer ........25 Unit Dimensions with Horizontal Venting ......5 Vent Restrictor Position ............. 25 Gas Line Dimensions ............5 Reversible Flue Collar ............
safety decal This is a copy of the label that accompanies NOTE: Regency units are constantly being ® each Direct Vent Freestanding Gas Stove. We improved. Check the label on the unit and if have printed a copy of the contents here for there is a difference, the label on the unit is your review.
dimensions Unit Dimensions With Vertical Venting 18-13/16" (478mm) 22-1/8" (562mm) 17-1/4" (437mm) 19-5/16" (490mm) Unit Dimensions With Horizontal Venting Gas Line Dimensions 22-13/16" (579mm) 18-13/16" (478mm) 4-5/16" (110 mm) knock out 4-5/16” knock out If exiting from base of appliance (110 mm) gas line Gas line-If exiting from...
MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Intertek as a Direct Vent Wall Furnace to the following ® standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2019 / CSA 2.33-2019 and CSA 2.17-2017. This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with...
WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow the steps outlined below for each appliance connected to the venting system being placed into operation could result in carbon monoxide poisoning or death. The following steps shall be followed for each appliance connected to the venting system being placed into operation, while all other appliances connected to the venting system are not in operation: 1.
installer's information MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
installation Gas Installation Checklist REGENCY GAS INSTALLATION CHECKLIST This general checklist does not contain all pertinent installation details or specifics and does not supersede the guidelines in this manual. Your Regency dealer/installer should use it in conjunction with manual instructions. Please follow all local codes and jurisdictions in authority. Customer: Date Installed: Install Address:...
Page 10
installation REGENCY GAS INSTALLATION CHECKLIST Finishing If applicable, is only noncombustible material installed in the noncombustible areas? Do clearances meet installation and manual requirements? Do the mantels and/or projections comply with the installation manual? If applicable, was the solid fuel fireplace warning plate installed? Appliance Media Setup Do commands from the remote or wall switch light the pilot and main burner? Are the burner media/log set, glass door, and screen installed per instructions in the manual?
owner's information Remote/Receiver Coding To code the receiver to the hand held remote, follow the procedure below. 1. Open the lower door on the unit. 2. Plug in 120 volt power cord into a grounded receptacle or install 4 AA batteries into battery pack and plug into battery terminals located near the gas valve.
owner's information Important Message This appliance installation must comply with the WARNING: FAILURE TO INSTALL THIS manufacturer's installation instructions and local SAVE THESE INSTRUCTIONS APPLIANCE CORRECTLY WILL VOID codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 YOUR WARRANTY AND MAY CAUSE The RC500E Direct Vent Freestanding Gas...
owner's information Lighting Procedure Shutdown Procedure IMPORTANT: The remote control system supplied with this appliance has several options for starting/operating the appliance using the power button and ON/OFF key on the hand held transmitter. 1. Press the ON/OFF button on the remote Prior to operating this appliance, please read the remote control operat- ing instructions (packaged with remote control) to understand how to 2.
owner's information Copy of the Lighting Plate Instructions FOR YOUR SAFETY READ BEFORE LIGHTING POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
owner's information Proflame 2 Remote Control Operating Instructions IMPORTANT:The Proflame Transmitter 2 is an integrated part of the TECHNICAL DATA Proflame 2 System, which consists of these elements: REMOTE CONTROL • Proflame 2 Transmitter, to be used in conjunction with: •...
Page 16
owner's information Temperature Indication Display Remote-Flame Control With the system in the "OFF" position, press the Thermostat Key and the The Proflame has six (6) flame levels. With the system on, and the Mode Key at the same time. Look at the LCD screen on the transmitter flame level at the maximum in the appliance, pressing the Down Arrow to verify that a C or F is visible to the right of the room temperature Key once will reduce the flame height by one step until the flame is...
Page 17
owner's information Smart Thermostat (Transmitter Operation) Remote Dimmer Control (Light)** The auxiliary function controls the AUX power outlet by the dimmable The Smart Thermostat function adjusts the flame height in accor- light control. To activate this function use the Mode Key (fig. 1) to dance to the difference between the set point temperature and the index to the AUX icon (fig.
Page 18
maintenance Continuous Pilot/Intermittent Pilot (CPI/IPI) Key Lock selection This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE and UP Keys at the same Note: Power vent models do not have a Continu- time (fig.
owner's information First Fire NOTE: This appliance will operate with 4 AA back-up batteries installed (see Back-up Battery section for details) during power outages. Only the The first fire in your stove is part of the paint curing fan and light will not operate until power is process.
owner's information Opening the Front Glass Door 1. Open lower door on unit by pulling forward. 2. Locate latch behind right handle, pull latch down. 3. Front of latch will drop down and release door handle. Pull door handle forward to open door. Handle Latch located behind handle...
owner's information Safety Screen Installation / Removal The safety screens must be installed and kept on the unit at all times. 1. Remove stove top—see instructions in manual. t t o o o o l l t t i i p p 2.
owner's information General Vent Maintenance Glass Replacement 5. Side glass panels can be replaced in the same manner as the front glass - but there are only 2 brackets securing each piece of side glass as Your stove is supplied with high temperature, 5 Conduct an inspection of the venting system semi- shown below.
owner's information Outside Side Glass Accent Light Bulb Fan Maintenance / t t o o o o l l t t i i p p Replacement Replacement Replacement If your fan requires maintenance or replacement, 1. Turn off stove and allow it to return to room 1.
installer's information General Safety Information Installation Checklist 1. Provide adequate clearances for servicing, proper operation and around the air openings into the combustion chamber. 1. Locate your appliance. Refer to the following 1. The appliance installation must conform with sections: local Canadian Electrical Code.
installation Venting Introduction Installation Precautions Safety Precautions for the Installer The Horizontal Termination Kit and other approved These venting systems are engineered products venting systems as per table on next page, in that have been designed and tested for use with 1.
installation Exterior Vent Terminal Locations Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) 22"(56cm) 22"(56cm) from the center line of the terminal (check with the local code)
installation t t o o o o l l t t i i p p Clearances to Combustibles Locating Your Gas Stove Accent Light Bulb Install 1. Turn off stove and allow to return to room When selecting a location for your stove, ensure The clearances listed are MINIMUM distances.
installation 4” x 6-5/8” Rigid Pipe Cross Reference Chart Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Note: Olympia Ventis DV venting is only approved for certain models. See list of approved models in cross-reference chart. 4"...
Page 29
installation Description Simpson *Selkirk *American Metal *Metal-Fab™ *Security *ICC Excel *Olympia Direct Vent Pro ® Direct Temp™ Products® Sure Seal Secure- Vent® Direct Ventis DV*** Amerivent Direct Attic Insulation Shield 12" 46DVA-IS 4DAIS12 4DIS SV4RSA VDV-AIS04 Attic Insulation Shield 4DAIS12 TM-4AS - Cold Climates 36"...
installation Venting Arrangements - Vertical Venting Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations. Maximum one 90 elbow (two 45 elbows equal one 90 elbow). Important: The IPI/CPI switch on the hand-held remote control transmitter must be turned to CPI (Continuous Pilot Ignition) at all times.
installation Venting Arrangements - Horizontal Venting Vent Restrictor Set 2 No Vent Restrictor (Factory Set) 40-5/16" (1022mm) **Note: If termination is rear vented at a minimum to centerline height of 40-5/16" (1022 mm) and horizontal length greater than 12" (305 mm) to a maximum of 18" (457 mm), only a rear vent riser or snorkel may be used. See manual for details. | RC500E-11...
Page 33
installation Horizontal Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option H + H1 With these options, maxi- mum total pipe length is 30 2' Min. 4' Max. feet with minimum of 6 feet total vertical and maximum 3' Min.
Page 34
installation Vertical Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option V V + V1 With these options, max. total pipe length is 30 feet with min. 1' Min. 4' Max. 2' Min. of 6 feet total vertical and max. 2' Min.
installation Co-Linear 3" - 3" Flex Pipe Venting (Masonry Chimney Applications Only) Important: The IPI/CPI switch on the hand-held remote control transmitter must be turned to CPI (Continuous Pilot Ignition) at all times. This will avoid nuisance pilot outages during operation of this appliance when using these venting configurations on this page. See Remote manual for setup of this IPI/CPI switch.
installation Vertical Termination With Co-Linear Flex System Masonry chimneys may take various contours which the flexible liner will THE APPLIANCE MUST NOT BE accommodate. However, keep the flexible liner as straight as possible, CONNECTED TO A CHIMNEY FLUE avoid unnecessary bending. SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.
installation Direct Vent Stove Horizontal Vent Kit Direct Vent 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the RC500E Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent sys- AstroCap Thimble...
Page 38
installation 12. Install the spring spacers onto the pipe sections. 13. Secure the 4" dia. flex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel). 14.
installation Residential and Manufactured Homes / Mobile Homes Minimum Horizontal Termination Installations Planning Your Venting Installation Note: These are the minimum pieces required. Other parts may be required for See the "Exterior Vent Terminal Locations" your particular installation. section for requirements. Minimum components for a Horizontal Installation: When planning your installation, it will be necessary 380-946...
Page 40
installation Residential and Manufactured Homes / Mobile Homes Minimum Horizontal Termination Installations Planning Your Venting Note: These are the minimum pieces required. Other parts may be required Installation for your particular installation. See the "Exterior Vent Terminal Locations" Minimum components for a Horizontal Installation: section for requirements.
installation Dura-Vent Termination Kit Planning Your Dura-Vent Warning: Always maintain required Be sure to check the vent termination clearance requirements from decks, windows, soffits, gas Installation clearances (air spaces) to nearby regulators, air supply inlets and public walkways as combustibles to prevent a fire specified in the "Exterior Vent Terminal Locations"...
installation 2. Assemble the desired combination of pipe and NOTE: For Snorkel terminations in ABOVE You will require the following components with your elbow to the appliance adapter with pipe seams new Direct Vent Freestanding Gas Stove. Please oriented down. Offset the pipe seams as double grade installations, follow national review your product to make sure you have every- seams in one place will cause the outer pipe to...
installation If installing riser vent terminal, follow steps c) Before connecting the vent pipe to the below: vent termination, slide the black deco- rative wall thimble cover over the vent 1. Take the Riser Vent terminal and separate pipe, then slide the Wall Penetration the Backing Plate from the Riser Vent Front Heat Shield over the vent pipe.
Page 44
installation 6. Continue to assemble pipe lengths. 7. Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails, Note: If an offset is necessary in the slide storm collar over the pipe section and attic to avoid obstructions, it is seal with a mastic.
installation Converting Class A Metal 4. Pass the flex pipe down through the center of the chimney system, and center the adaptor Chimney to Direct Vent System Termination on the top of the chimney pipe. Drill four 1/8" diameter holes through the adaptor and into Top Adaptor the chimney top.
installation Note: If you are using a 6" square 8. Ensure vent is vertical and secure the base of Since some municipalities have additional local the flashing to the roof with roofing rails, slide support you may find it difficult codes it is always best to consult with your local storm collar over the pipe section and seal with authorities and the CAN/CGA B149 installation...
installation 885 S.I.T. Valve Description Aeration Adjustment Caution: Carbon will be produced if the air shutter is closed too much. 1) 6 Stage flame adjustment The burner aeration is factory set but may need 2) Pilot adjustment Note: Any damage due to carboning adjusting due to either the local gas supply, air 3) Inlet Pressure Tap resulting from improperly setting...
installation Opening the Front Glass Door 1. Open lower door on unit by pulling forward. 2. Locate latch behind right handle, pull latch down. 3. Front of latch will drop down and release door handle. Pull door handle forward to open door. Handle Latch located behind handle...
installation Front Grill Removal / Installation The front grill is easily removed to allow easier access for removing the burner or inner panels - follow steps below to remove. 1. Remove 2 screws from the front of 2. Slide out lower plate securing the grill, then lift 3.
RC500E installation ENAMEL PANEL INSTALLATION Enamel Panel Installation Remove the 2 lower screws to remove the steel inner panels. Shut off the unit and allow to cool to room temperature. tooltip Lift off the front safety screen (if installed) and open the front door (see details in manual).
installation RC500E-11 Conversion Kit From NG to LP CONVERSION KIT FROM NG TO LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Loosen both screws on pilot hood cover. Pivot cover to the left WARNING to reveal pilot hood.
Page 52
installation 19. Reverse steps 6 through 1. 13. Disconnect the NG stepper motor wires from the IFC (Intermittent Fireplace Control) in locations shown below. 20. Ensure the pilot light is in the correct orientation to the Burner. Reconnect the gas and electrical supply to the appliance. Start the appliance.
RC500E installation LOG INSTALLATION Log Set Installation Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty. *Paint is included if touch ups are required.
Page 54
RC500E installation 8. Ensure Logs 2 & 3 are still connected after installing onto the burner. 11. Install Log 5 - place darker end of the log into the triangle created From the left side - push left side of Log 1 forward until it is touching by Logs 1,2 &...
Page 55
RC500E installation 14. 3lb of glass crushed glass installed on the burner - there will be 17. Log 7 should touch Log 3 when in position, as shown below. 1/2lb leftover. Log 7 placement Glass Crystal amount 18. Place the glowing wool on the crushed glass as shown below. 15.
installation Optional Media - Crushed Glass and Volcanic Stone Installation A combination of glass crystals and volcanic stones can be installed on the burner as an option to the log set. Shut off the gas and electrical supply. 1. Remove the safety screen and open the front door of the unit. 2.
installation Optional Wall Thermostat Final Check Manual Operation (No Remote) A wall thermostat may be installed if desired. To override the remote - open the front lower door Before leaving this unit with the customer, the Connect the wires as per the wiring diagrams. and locate the reset button.
installation Wiring Diagram Without Thermostat If any of the original wires as supplied with the appliance must be replaced, it must be replaced with CSA type SEW (200 C) or its equivalent. This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate.
operating instructions Wiring Diagram With Thermostat SPARK GREEN MAIN BLACK LINE BLACK FLAME DETECT Thermostat( Optional) (Millivolt) GREY BATTERY HOLDER GREY ON/OFF ON/OFF SWITCH BAT -/+ IPI/CPI EV GND YELLOW/GREEN EV P/M ORANGE GREEN BLACK MOTOR BROWN YELLOW ORANGE SPLIT FLOW BLACK BLACK BLACK...
operating instructions Lighting Procedure Note: The first try for ignition will last approximately 60 seconds. If there is no flame ignition (rectification) the board will stop sparking for approximately IMPORTANT: The remote control system supplied with this appliance has 35 seconds. After wait time , the board will start second try for ignition by several options for starting/operating the appliance using the power button sparking for approximately 60 seconds.
operating instructions Copy of the Lighting Plate Instructions FOR YOUR SAFETY READ BEFORE LIGHTING POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
maintenance Normal Operating Sounds of 2. Clean glass (never when unit is hot), appliance, CAUTION: ANY SAFETY SCREEN and door with a damp cloth. Never use an Gas Appliances OR GUARD REMOVED FOR SER- abrasive cleaner. VICING AN APPLIANCE MUST BE 3.
maintenance t t o o o o l l t t i i p p Accent Light Bulb Glass Gasket 4. Remove burner (see instructions in this manual). Replacement If the glass seal on the appliance requires 846-685 5/8" Alum F.Core w/sml Tail replacement a graphite seal specifically designed 1.
maintenance Gas Maintenance Gas Maintenance Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check. Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox, increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually. Clean Inspect Check • Glass • Pilot assembly • Voltage on thermocouple/thermopile (mil- • Interior bricks / panels • Burner livolt models) • Burner ports & burner air shutter • Pressure relief gaskets/doors • Ohms reading on flame sense (electronic •...
parts list Main Assembly 6 7 8 9 12 RC500E-11 |...
Page 66
parts list Main Assembly 366-574/P Valve Assembly - NG 366-776/P Valve Assembly - LP 911-084 Novasit Valve NG 885 SIT IPI 0.885.001 911-085 Novasit Valve LP 885 SIT IPI 0.885.002 904-162 Burner Orifice #43 NG 904-163 Burner Orifice #54 LP 911-276 Pilot Assembly IPI NG 2 Flame 911-277...
Page 67
parts list Main Assembly 366-082 Inner Back Curved Panel 366-051 Top Baffle 366-107 Light Housing 366-108 Light Shield 911-072 Halogen bulb G9/120V/25W (High Temp) 366-085 Air Adjustment Cover Plate 932-009 Tubing SS Flexible 3/8 x 9 inch 904-599 Fitting Elbow 90 Degree (Located At Orifice End) 904-633 Connector 3/8 Comp x 3/8 Male 904-600...
warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U.S., Inc. (for U.S. customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
Page 71
warranty At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof of purchase by you).
Page 72
warranty Limitations of Liability: The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL DAMAGES OR DAMAGES TO PROPERTY.
Page 73
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.