General Vent Maintenance

Conduct an inspection of the venting system semi-
annually. Recommended areas to inspect as follows:
1. Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2. Remove the Cap, and shine a flashlight down the
Vent. Remove any bird nests, or other foreign
material.
3. Check for evidences of excessive condensation,
such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4. Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.
5. Verify proper operation after servicing.

Log Replacement

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the logs.
The pilot light generates enough heat to burn
someone. If for any reason a log should need re-
placement, you must use the proper replacement
log. The position of these logs must be as shown
in the diagram under Log Installation.
Note:
Improper positioning of logs
may create carbon build-up and
will alter the unit's performance
t t o o o o l l t t i i p p
which is not covered under
warranty.
22
| RC500E-11

Glass Replacement

Your stove is supplied with high temperature, 5
mm Neoceram ceramic glass that will withstand
the highest heat that your unit will produce. In
the event that you break your glass by impact,
purchase your replacement door from an authorized
Regency
dealer only, and follow our step-by-step
®
instructions for replacement.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the
glass front or with a cracked or broken
glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualified service per
son.
WARNING: Do not operate appliance
with the glass front removed, cracked, or
broken. Replacement of the glass should
be done by a licensed or qualified service
person.
1. Turn off unit and allow to cool to room tem-
perature.
2. Open front glass door (see details in this manual).
3. Remove 4 bolts and brackets to release front glass.
4. Replace glass and gasket-- secure with same
brackets and bolts removed in Step 3.
5. Side glass panels can be replaced in the same
manner as the front glass - but there are only
2 brackets securing each piece of side glass as
shown below.
Front Door Glass Brackets
Side Glass Brackets