Disassembly & Reassembly - Pu 3000 Pneumatic, Pu 3000 Airmix; Mixer; Piloted Valves; Cartridge Of A Fluid Valve (Ind. 9A / 9B / 9C / 9D) (Refer To Doc. 573.188.050) - SAMES KREMLIN PU3000 2L 53/1 Translation From The Original Manual

Electronic mixing machine
Table of Contents

Advertisement

17. DISASSEMBLY & REASSEMBLY - PU 3000 PNEUMATIC, PU 3000
AIRMIX
CAUTION : Before any work is carried on the pump, stop the machine after
carrying out flushing, shut off the compressed air supply and depressurize the
circuits triggering the gun.
The pump is manufactured under the ATEX agreement and can not be modified.
SAMES KREMLIN will not be held responsible for any failure to comply with that

MIXER

Unscrew the mixer assembly and replace it with a new one.

PILOTED VALVES

CARTRIDGE OF A FLUID VALVE (IND. 9A / 9B / 9C / 9D) (REFER TO DOC. 573.188.050)

C 2
A 1
Unscrew the 3 screws (7).
Extract the valve from the module body.
Unscrew the needle (1a / 1b).
Unscrew the cylinder (4a / 4b).
Hold rod carrier (6), unscrew the needle rod and remove cartridge with rod assembly (9a
/ 9b / 9c / 9d). Remove the seals.
SAMES KREMLIN
instruction.
C 2
Page 45
A 1
A 1
Manual : 573.199.112