TROUBLESHOOTING

For any intervention on the machine :
- Flush the circuits,
- Shut off the compressed air,
- Depressurize the hoses by triggering the gun,
- Shut off the electric supply.
If a problem occurs during the machine operation, alarms will be displayed on the screen of the
machine.
OK
Input
to disable each alarm.
TROUBLES




SAMES KREMLIN
CAUSES
Trouble on the BASE fluid section
Trouble on the CATALYST fluid
section
Incorrect mixing ratio
Flow incorrectly adjusted
Irrelevant data capture between the
ratio
and
the
injection
(Machine
unable
to
parameters requested)
Page 37
Check the BASE circuit :
- material in the drum,
- suction rod strainer,
- pump valves.
Clean or change.
Check the CATALYST pressure towards
the BASE pressure.
Check the CATALYST circuit :
- material in the drum,
- suction rod strainer,
- pump valves.
Clean or change.
Check the CATALYST pressure towards
the BASE pressure.
Check the material levels in the supply
drums.
Check the starting of the pumps.
Check the CATALYST pressure towards
the BASE pressure.
Check that the P1 parameter (ratio) and
volume
the P6 parameter (injection volume) are
give
the
compatible in injection capability terms
in
relation
(refer to § 12).
SOLUTIONS
to
the
ratio
requested
Manual : 573.199.112