CONNECTION OF THE CONTROL BOX AND OF THE FLUID FRAME

The PU 3000 must be connected to
a dry and clean compressed air
network (minimum 4 bar / 58 psi) and
to a single phase electric supply (115V
/ 230V) connected to an isolating
switch. The electric supply must have
an appropriate protection (30 mA).The
network ground will be connected in
the control box on a connect provided
and identified with the symbol
Before connecting the PU
3000, be certain the mains voltage is
the same as the one of the machine
(230 V).
If no, open the electric box removing
the protective housing and move the
jumper (230V  115V).
The machines with a stabilized electric
supply tolerate all voltage types (115V /
230V).
Connect the air equipment of the PU
3000 to the pneumatic network with a
conductive hose (minimum 16 mm / 5/8
dia).
Nota : these hoses are not supplied
in the standard version.
The air connection of the machine is
Female 3/4 BSP (air inlet valve).
The connection between the control
box and the electrovalves located on
the frame, is carried out via cable,
length : 8 m / 26.2".
Between the mixer outlet and the spray
gun, you must install a fluid hose,
model HP (high pressure) (
according to the pressures the pumps
supply).
SAMES KREMLIN
for machine with serial number < to 09Y1080
.
for machine with serial number >to 09Y1080
Machine with a stabilized electric supply
act
Page 16
Fuse 160 mA
Fuse 315 mA
Manual : 573.199.112